Since the inception of dental implants, a steadily increasing prevalence of peri-implantitis has been documented. Irrespective of the treatment protocol applied for the management of peri-implantitis, this biofilm-associated pathology, continues to be a clinical challenge yielding unpredictable and variable levels of resolution, and in some cases resulting in implant loss. This paper investigated the effect of microcosm biofilm in vitro decontamination on surface topography, wettability, chemistry, and biocompatibility, following decontamination protocols applied to previously infected implant titanium (Ti) surfaces, both micro-rough -Sandblasted, Large-grit, Acid-etched (SLA)-and smooth surfaces -Machined (M). Microcosm biofilms were grown on SLA and M Ti discs. These were treated with TiBrushes (TiB), combination of TiB and photodynamic therapy (PDT), combination of TiB and 0.2%CHX/1%NaClO, plus or minus Ultraviolet-C (UV-C) radiation. Surface topography was evaluated by Scanning Electron Microscopy (SEM) and Laser Surface Profilometry. Surface function was analysed through wettability analysis. Surface chemistry evaluation of the discs was performed under SEM/Energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS). Biocompatibility was tested with the cytocompatibility assay using human osteoblast-like osteosarcoma cell line (MG-63) cells. Elemental analysis of the discs disclosed chemical surface alterations resulting from the different treatment modalities. Titanium, carbon, oxygen, sodium, aluminium, silver, were identified by EDX as the main components of all the discs. Based on the data drawn from this study, we have shown that following the decontamination of Ti surfaces the biomaterial surface chemistry and topography was altered. The type of treatment and Ti surface had a significant effect on cytocompatibility ( = 0.0001). Although, no treatment modality hindered the titanium surface biocompatibility, parameters such as the use of chemical agents and micro-rough surfaces had a higher cytotoxic effect in MG-63 cells. The use of smooth surfaces, and photofunctionalisation of the TiO layer had a beneficial effect on cytocompatibility following decontamination.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9456268 | PMC |
http://dx.doi.org/10.3390/ijms231710033 | DOI Listing |
Polymers (Basel)
January 2025
Institute of Biochemistry and Genetics, Subdivision of the Ufa Federal Research Center of the Russian Academy of Sciences, Ufa 450054, Russia.
Biomimetic patterning emerges as a promising antibiotic-free approach to protect medical devices from bacterial adhesion and biofilm formation. The main advantage of this approach lies in its simplicity and scalability for industrial applications. In this study, we employ it to produce antibacterial coatings based on silicone materials, widely used in the healthcare industry.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
Jožef Stefan Institute, Department of Physical and Organic Chemistry, Jamova c. 39, SI-1000 Ljubljana, Slovenia.
The study aimed to develop a superhydrophobic coating on the aluminium alloy 2024-T3 surface. The desired surface roughness and low surface energy were achieved with SiO nanoparticles, synthesised via the Stöber method and modified with alkyl silane (AS) or perfluoroalkyl silane (FAS). To enhance particle adhesion to the alloy substrate, nanoparticles were incorporated into a hybrid sol-gel coating composed of tetraethyl orthosilicate, methyl methacrylate, and 3-methacryloxypropyl trimethoxysilane.
View Article and Find Full Text PDFJ Clin Med
January 2025
Ophthalmology Section, Department of Medicine and Surgery, University of Perugia, 06132 Perugia, Italy.
To report the cosmetic, clinical, and visual outcomes of a combined surgical approach for treating a corneal/limbal dermoid using excision and a three-layered amniotic membrane graft with fibrin glue. An 18-year-old female presented with impaired vision and ocular discomfort caused by a prominent dome-shaped limbal congenital dermoid on the inferotemporal cornea, resulting in a significant aesthetic concern. A full assessment, including refraction, best-corrected visual acuity (BCVA), corneal topography, aberrometry and anterior segment OCT (AS-OCT) was conducted to plan the surgical approach.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
School of Engineering, University of Liverpool, Liverpool, L69 3GH, United Kingdom.
Hypothesis: We hypothesise that superhydrophobic surfaces can achieve effective interfacial slip and drag reduction even under non-Newtonian, shear-thinning fluid flows. Unlike Newtonian fluids, where slip is primarily influenced by viscosity and surface tension, we anticipate that the shear-thinning nature of these fluids may enhance slip length and drag reduction.
Experiments And Numerical Analysis: The superhydrophobic surfaces used in this study, featuring a dual-scale random topography, were fabricated via a spray coating process, and low-concentration xanthan gum solutions (50-250 ppm) were used as model shear-thinning fluids of low elasticity.
J Biomed Mater Res B Appl Biomater
February 2025
McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania, USA.
Cardiovascular diseases (CVDs) were responsible for approximately 19 million deaths in 2020, marking an increase of 18.7% since 2010. Biological decellularized patches are common therapeutic solutions for CVD such as cardiac and valve defects.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!