Evaluation of oocyte maturity using artificial intelligence quantification of follicle volume biomarker by three-dimensional ultrasound.

Reprod Biomed Online

Department of Ultrasound Medicine, the Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China; The Seventh Affiliated Hospital University of South China, Hunan Veterans Administration Hospital, Changsha, China; The First Affiliated Hospital, Medical Imaging Centre, Hengyang Medical School, University of South China, Hengyang, China; Institution of Medical Imaging, University of South China, Hengyang, China. Electronic address:

Published: December 2022

Research Question: Can a novel deep learning-based follicle volume biomarker using three-dimensional ultrasound (3D-US) be established to aid in the assessment of oocyte maturity, timing of HCG administration and the individual prediction of ovarian hyper-response?

Design: A total of 515 IVF cases were enrolled, and 3D-US scanning was carried out on HCG administration day. A follicle volume biomarker established by means of a deep learning-based segmentation algorithm was used to calculate optimal leading follicle volume for predicting number of mature oocytes retrieved and optimizing HCG trigger timing. Performance of the novel biomarker cut-off value was compared with conventional two-dimensional ultrasound (2D-US) follicular diameter measurements in assessing oocyte retrieval outcome. Moreover, demographics, infertility work-up and ultrasound biomarkers were used to build models for predicting ovarian hyper-response.

Results: On the basis of the deep learning method, the optimal cut-off value of the follicle volume biomarker was determined to be 0.5 cm for predicting number of mature oocytes retrieved; its performance was significantly better than the conventional method (two-dimensional diameter measurement ≥10 mm). The cut-off value for leading follicle volume to optimize HCG trigger timing was determined to be 3.0 cm and was significantly associated with a higher number of mature oocytes retrieved (P = 0.01). Accuracy of the multi-layer perceptron model was better than two-dimensional diameter measurement (0.890 versus 0.785) and other multivariate classifiers in predicting ovarian hyper-response (P < 0.001).

Conclusions: Deep learning segmentation methods and multivariate classifiers based on 3D-US were found to be potentially effective approaches for assessing mature oocyte retrieval outcome and individual prediction of ovarian hyper-response.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rbmo.2022.07.012DOI Listing

Publication Analysis

Top Keywords

follicle volume
24
volume biomarker
16
number mature
12
mature oocytes
12
oocytes retrieved
12
oocyte maturity
8
biomarker three-dimensional
8
three-dimensional ultrasound
8
deep learning-based
8
hcg administration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!