Objective:  The aim of this study was to report the short-term clinical and radiographic outcome for the treatment of femoral capital physeal fractures with cortical positional screws in cats.

Study Design:  Medical records and radiographs of cats with femoral capital physeal fractures stabilized with cortical positional screws were retrospectively reviewed. Signalment, bodyweight, femoral head affected, fracture classification, fracture reduction, implants, concurrent orthopaedic injuries, osteoarthritis, femoral neck osteolysis, complications and 6-week follow-up clinical results were recorded. A short- to long-term follow-up was performed by telephone questionnaire with the owners.

Results:  Forty-six fractures in 39 cats met the inclusion criteria. In 45/46 fractures, radiographic signs of bone healing were present and 35/39 cats were assessed as walking normally by a veterinarian at 6-week follow-up. There was a significant increase in radiographic signs of osteoarthritis (=0.037) and femoral neck osteolysis (=0.001) on 6-week follow-up radiographs. Pre- and postoperative osteoarthritis and femoral neck osteolysis were not associated with clinical outcome. The mean follow-up period for the telephone questionnaire was 48 months (range, 5-147 months). Seven out of 25 owners reported a gait abnormality in the short- to long-term.

Conclusion:  Femoral capital physeal fractures in cats can be treated successfully with the use of cortical positional screws. This technique may be considered as an alternative to other primary fixation techniques and salvage procedures for the treatment of femoral capital physeal injuries in cats. This technique seemed successful in cats with a low-grade preoperative femoral neck osteolysis.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0042-1750430DOI Listing

Publication Analysis

Top Keywords

capital physeal
20
femoral capital
16
physeal fractures
16
cortical positional
16
positional screws
16
femoral neck
16
neck osteolysis
16
6-week follow-up
12
femoral
9
short-term clinical
8

Similar Publications

Slipped capital femoral epiphysis (SCFE) is a common adolescent hip condition, most often seen during periods of rapid bone growth. Deficiency in thyroid hormone levels can lead to reduced bone turnover and altered epiphyseal plate activity, which may influence the outcome of SCFE pinning and other orthopedic interventions crossing the epiphysis of the femur. Our patient was a 12-year-old female child with a two-month history of atraumatic right hip pain who presented with bilateral slipped capital femoral epiphysis (SCFE) and underwent successful bilateral in situ pinning.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness and precision of using 3D-printed guides versus freehand methods for placing Kirschner wires in the femurs of dogs, focusing on novice versus experienced surgeons.!
  • It involved creating 3D models of dog femurs, followed by virtual surgical planning, and then comparing the results of wire placements with freehand techniques and those guided by 3D-printed models.!
  • Results indicated that 3D-printed guides led to quicker procedures, fewer complications, and better accuracy in wire placement, highlighting the need for further research in practical applications for surgeries in dogs.!
View Article and Find Full Text PDF

Slipped capital femoral epiphysis: emphasis on early recognition and potential pitfalls.

Skeletal Radiol

September 2024

Department of Orthopaedic Surgery, BC Children's Hospital, University of British Columbia, Vancouver, BC, Canada.

Article Synopsis
  • Recent research emphasizes the role of femoral head shape and minor instability in the growth plate as early indicators of SCFE, which can be seen in imaging before a full slip occurs.
  • To improve diagnosis, it's important to examine the growth plate's structure and compare it to the healthy hip; using cross-sectional imaging judiciously can help clarify early cases and guide treatment for more severe instances.
View Article and Find Full Text PDF

Objective: To report a capital physeal fracture as the result of a bone infarction with subsequent neoplastic transformation 4 years following total hip replacement.

Study Design: Case report.

Animals: Five-year-old female spayed golden retriever.

View Article and Find Full Text PDF

Modified Dunn Procedure for Open Reduction of Chronic Slipped Capital Femoral Epiphysis.

JBJS Essent Surg Tech

July 2024

Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Article Synopsis
  • Abnormal femoral head shape from slipped capital femoral epiphysis (SCFE) can lead to hip problems like femoroacetabular impingement and early osteoarthritis, making surgical correction important to restore hip anatomy.
  • The modified Dunn procedure offers a surgical approach that aims to correct the anatomy of the hip without damaging the blood supply to the femoral head, reducing the risk of osteonecrosis.
  • The procedure involves a careful dislocation of the hip and meticulous shaping of bones while maintaining blood vessel integrity, allowing for effective repositioning and fixation of the femoral head.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!