Originally developed for use in controlled laboratory settings, potentiometric ion-selective electrode (ISE) sensors have recently been deployed for continuous, in situ measurement of analyte concentration in agricultural (e.g., nitrate), environmental (e.g., ocean acidification), industrial (e.g., wastewater), and health-care sectors (e.g., sweat sensors). However, due to uncontrolled temperature and lack of frequent calibration in these field applications, it has been difficult to achieve accuracy comparable to the laboratory setting. In this paper, we propose a novel temperature self-calibration method where the ISE sensors can serve as their own thermometer and therefore precisely measure the analyte concentration in the field condition by compensating for the temperature variations. We validate the method with controlled experiments using pH and nitrate ISEs, which use the Nernst principle for electrochemical sensing. We show that, using temperature self-calibration, pH and nitrate can be measured within 0.3% and 5% of the true concentration, respectively, under varying concentrations and temperature conditions. Moreover, we perform a field study to continuously monitor the nitrate concentration of an agricultural field over a period of 6 days. Our temperature self-calibration approach determines the nitrate concentration within 4% of the ground truth measured by laboratory-based high-precision nitrate sensors. Our approach is general and would allow battery-free temperature-corrected analyte measurement for all Nernst principle-based sensors being deployed as wearable or implantable sensors.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.2c01163DOI Listing

Publication Analysis

Top Keywords

temperature self-calibration
16
ise sensors
8
sensors deployed
8
analyte concentration
8
concentration agricultural
8
nitrate concentration
8
temperature
7
sensors
6
nitrate
6
concentration
5

Similar Publications

Acoustically levitated droplets in the nanoliter to microliter range are studied in various fields. The volume measurements of these are conventionally done using image analysis. A precision-produced calibration sphere is often used to calibrate the recording equipment, which is time-consuming and expensive.

View Article and Find Full Text PDF

Paper-based triple-readout nanosensor for point-of-care detection of glucose in urine.

Biosens Bioelectron

February 2025

Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, College of Chemistry and Chemical Engineering, Harbin Normal University, Harbin, 150025, PR China. Electronic address:

Glucose detection is critical for diabetes diagnosis and management. This study aimed to develop an enzyme-free, cascade-based, triple-readout paper sensor utilizing bismuth (Bi)-based metal-organic frameworks/gold nanoparticles (Bi-BDC-NH@Au) for detecting urine glucose. Herein, Bi-BDC-NH@Au exhibited glucose oxidase-like activity and oxidized glucose to generate HO, which then quenched the blue fluorescence of FP@Bi-BDC-NH@Au through an inner filter effect.

View Article and Find Full Text PDF

In order to ensure the reliability and accuracy of long-term temperature measurement where the thermometers are discommodious or even impossible to access for conventional periodical calibration, a study on miniaturized in-situ self-calibrated (MISSC) thermometers based on Ga and Ga-Zn fixed points was conducted using temperature scale transfer technology. One MISSC thermometer consists of three parts: the first is the fixed-points hardware, including a container with two cells separately filled with Ga and Ga-Zn; the second is the temperature sensing hardware, made of a Type T thermocouple; the third is the mini-power heating hardware, made of a film resistance. The measurement and calibration (M&C) system comprises a temperature measurement and data processing subsystem and a mini-power heating control subsystem.

View Article and Find Full Text PDF

Improving the accuracy of large measurement systems consisting of multiple laser trackers and Enhanced Reference System (ERS) points is technically challenging. In practice, standard devices with precise distance limits are often used to improve the registration accuracy of laser trackers. However, these standard devices are expensive and need to be calibrated by the Coordinate Measuring Machine (CMM).

View Article and Find Full Text PDF

Electronic skins are expected to replicate a human-like tactile sense, which significantly detects surface information, including geometry, material, and temperature. Although most texture features can be sensed in the horizontal direction, the lack of effective approaches for detecting vertical properties limits the development of artificial skin based on tactile sensors. In this study, an all-printed finger-inspired tactile sensor array is developed to realize the 3D detection and reconstruction of microscale structures.

View Article and Find Full Text PDF