Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In synchrotron radiation X-ray imaging, the imaging field of view and spatial resolution are mutually restricted, which makes it impossible to have both a large field of view and high resolution when carrying out experiments. Constructing an oversampled image through the micro-scanning method and using the deconvolution algorithm to eliminate the point spread function introduced by pixel overlap can increase the resolution under a fixed imaging field of view, thereby improving the ratio of the field of view to the spatial resolution. In this paper, numerical simulation and synchrotron radiation experiments are carried out with a different number of micro-scanning steps. In numerical simulation experiments only affected by the image pixel size, as the number of micro-scanning steps increases, the ability of the oversampled image with deconvolution to improve the resolution is stronger. The achievable resolution of the oversampled image with deconvolution is basically the same as that of the sample image. In the synchrotron radiation experiments, the resolution of the oversampled image with deconvolution in the 2 × 2 mode is significantly improved. However, as the number of micro-scanning steps increases, the resolution improvement is limited, or even no longer improved. Finally, by analyzing the results of numerical simulation and synchrotron radiation experiments, three factors (four other factors affecting the resolution besides the camera resolution, translational accuracy of micro-scanning, and the signal-to-noise ratio of projections) affecting the micro-scanning method are proposed and verified by experiments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455207 | PMC |
http://dx.doi.org/10.1107/S1600577522007652 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!