Searching for literature data was performed in the PubMed, Scopus and eLIBRARY databases. In the second part, we considered modern classifications of endoleaks type 3, 4 and 5 after endovascular infrarenal abdominal aortic aneurysm repair, etiology, risk factors, classification of endoleaks. Modern data on effectiveness of their treatment by various methods are presented.

Download full-text PDF

Source
http://dx.doi.org/10.17116/hirurgia2022091115DOI Listing

Publication Analysis

Top Keywords

infrarenal abdominal
8
abdominal aortic
8
aortic aneurysm
8
aneurysm repair
8
[endoleaks endovacular
4
endovacular infrarenal
4
repair ii]
4
ii] searching
4
searching literature
4
literature data
4

Similar Publications

Objective: As aneurysmal disease is progressive, proximal disease progression and para-anastomotic aneurysms are complications experienced after open infrarenal abdominal aortic aneurysm repair (AAA). As such, fenestrated or branched endovascular repair (F/BEVAR) may be indicated in these patients. Data describing fenestrated endovascular aneurysm repair after prior open repair are limited to institutional databases.

View Article and Find Full Text PDF

Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).

Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.

View Article and Find Full Text PDF

The gender gap following infrarenal abdominal aneurysm repair: how to close the gap?

Eur Heart J

January 2025

Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, Milan, MI 20122, Italy.

View Article and Find Full Text PDF

Introduction And Importance: Severe aortic stenosis (AS) and chronic obstructive pulmonary disease (COPD) significantly increase perioperative morbidity and mortality. This case report discusses the challenges of managing a 75-year-old male patient with severe AS and advanced COPD undergoing elective abdominal aortic aneurysm (AAA) repair.

Case Presentation: The patient presented with a 6.

View Article and Find Full Text PDF

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!