Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips.
Methods: This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou MSK Eye Hospital (October 2020 to November 2020). Sulcus-to-sulcus (STS) distance, lens thickness (LT), and clinical refraction were measured preoperatively. The ZZ ICL formula (provides the predicted vault height and refraction based on TICL size, intraocular meridian, power, and eye parameters, including STS distance and LT) was used to select TICL size and predict vault height and residual refraction, which was also compared with the STAAR software recommended. Vault and residual refraction were measured at 3 months postoperatively.
Results: The analysis included 168 eyes in 84 patients. Postoperative vault size was comparable to that predicted by the ZZ ICL formula (528 ± 193 vs. 545 ± 156 μm, P = 0.227). Vault prediction error (PE) by the ZZ ICL formula was within 100, 300, and 500 μm in 40.48%, 88.10%, and 100% of eyes, respectively. Spherical equivalent (SE) and absolute cylindrical refractive error were 0.36 ± 0.48 and 0.40 ± 0.31 D at 3 months postoperatively. The SE PE, absolute cylindrical PE, and percentages of eyes with an absolute cylindrical PE within ± 0.50 D and ± 1.00 D were lower for the ZZ ICL formula than for the STAAR software (P < 0.01).
Conclusions: Combining measurements obtained in UBM video clips with the ZZ ICL formula provides an effective method of sizing TICLs and predicting vault height and residual refractive error.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9454160 | PMC |
http://dx.doi.org/10.1186/s12886-022-02583-9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!