AI Article Synopsis

  • The study evaluated the diagnostic effectiveness of a new dopamine transporter tracer, [F]FE-PE2I PET/CT, in comparison to the established [I]FP-CIT SPECT method for diagnosing Parkinson's disease and related syndromes.
  • Ninety-eight patients underwent both imaging tests, with [F]FE-PE2I showing a high sensitivity of 94% and perfect specificity of 100%, while inter-reader agreement was similarly high for both methods.
  • Results indicated that [F]FE-PE2I PET/CT provides comparable diagnostic results to SPECT, suggesting it is a practical option for clinical use with better patient scan logistics.

Article Abstract

Background: Dopamine transporter (DAT) imaging of striatum is clinically used in Parkinson's disease (PD) and neurodegenerative parkinsonian syndromes (PS) especially in the early disease stages. The aim of the present study was to evaluate the diagnostic performance of the recently developed tracer for DAT imaging [F]FE-PE2I PET/CT to the reference standard [I]FP-CIT SPECT.

Methods: Ninety-eight unselected patients referred for DAT imaging were included prospectively and consecutively and evaluated with [F]FE-PE2I PET/CT and [I]FP-CIT SPECT on two separate days. PET and SPECT scans were categorized independently by two blinded expert readers as either normal, vascular changes, or mixed. Semiquantitative values were obtained for each modality and compared regarding effect size using Glass' delta.

Results: Fifty-six of the [I]FP-CIT SPECT scans were considered abnormal (52 caused by PS, 4 by infarctions). Using [F]FE-PE2I PET/CT, 95 of the 98 patients were categorized identically to SPECT as PS or non-PS with a sensitivity of 0.94 [0.84-0.99] and a specificity of 1.00 [0.92-1.00]. Inter-reader agreement for [F]FE-PE2I PET with a kappa of 0.97 [0.89-1.00] was comparable to the agreement for [I]FP-CIT SPECT of 0.96 [0.76-1.00]. Semiquantitative values for short 10-min reconstructions of [F]FE-PE2I PET/CT were comparable to longer reconstructions. The effect size for putamen/caudate nucleus ratio was significantly increased using PET compared to SPECT.

Conclusions: The high correspondence of [F]FE-PE2I PET compared to reference standard [I]FP-CIT SPECT establishes [F]FE-PE2I PET as a feasible PET tracer for clinical use with favourable scan logistics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9452620PMC
http://dx.doi.org/10.1186/s13550-022-00930-xDOI Listing

Publication Analysis

Top Keywords

[i]fp-cit spect
20
[f]fe-pe2i pet
16
[f]fe-pe2i pet/ct
16
dat imaging
12
[f]fe-pe2i
8
pet feasible
8
dopamine transporter
8
reference standard
8
standard [i]fp-cit
8
spect scans
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!