A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aerosol and splatter generation with rotary handpieces used in restorative and orthodontic dentistry: a systematic review. | LitMetric

Introduction: The COVID-19 pandemic has caused major disruptions in dental care globally, in part due to the potential for contaminated aerosol to be generated by dental activities. This systematic review assesses the literature for changes in aerosol-contamination levels when rotary instruments are used, (1) as distance increases from patient's mouth; (2) as time passes after the procedure; and (3) when using different types of handpieces.

Methods: The review methods and reporting are in line with PRISMA statements. A structured search was conducted over five platforms (September 2021). Studies were assessed independently by two reviewers. To be eligible studies had to assess changes in levels of aerosol contamination over different distances, and time points, with rotary hand instruments. Studies' methodologies and the sensitivity of the contamination-measurement approaches were evaluated. Results are presented descriptively.

Results: From 422 papers identified, 23 studies were eligible. All investigated restorative procedures using rotary instruments and one study additionally looked at orthodontic bracket adhesive material removal. The results suggest contamination is significantly reduced over time and distance. However, for almost all studies that investigated these two factors, the sizes of the contaminated particles were not considered, and there were inconclusive findings regarding whether electric-driven handpieces generate lower levels of contaminated particles.

Conclusion: Aerosol contamination levels reduce as distances, and post-procedure times increase. However, there was sparce and inconsistent evidence on the clearing time and no conclusions could be drawn. High-speed handpieces produce significantly higher levels of contamination than slow-speed ones, and to a lesser extent, micro-motor handpieces. However, when micro-motor handpieces were used with water, the contamination levels rose and were similar to high-speed handpiece contamination levels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9447949PMC
http://dx.doi.org/10.1038/s41405-022-00118-4DOI Listing

Publication Analysis

Top Keywords

contamination levels
12
systematic review
8
rotary instruments
8
aerosol contamination
8
micro-motor handpieces
8
levels
7
contamination
6
handpieces
5
aerosol
4
aerosol splatter
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!