Understanding the lower urinary tract (LUT) and development of highly needed novel therapies to treat LUT disorders depends on accurate techniques to monitor LUT (dys)function in preclinical models. We recently developed videocystometry in rodents, which combines intravesical pressure measurements with X-ray-based fluoroscopy of the LUT, allowing the in vivo analysis of the process of urine storage and voiding with unprecedented detail. Videocystometry relies on the precise contrast-based determination of the bladder volume at high temporal resolution, which can readily be achieved in anesthetized or otherwise motion-restricted mice but not in awake and freely moving animals. To overcome this limitation, we developed a machine-learning method, in which we trained a neural network to automatically detect the bladder in fluoroscopic images, allowing the automatic analysis of bladder filling and voiding cycles based on large sets of time-lapse fluoroscopic images (>3 hr at 30 images/s) from behaving mice and in a noninvasive manner. With this approach, we found that urethane, an injectable anesthetic that is commonly used in preclinical urological research, has a profound, dose-dependent effect on urethral relaxation and voiding duration. Moreover, both in awake and in anesthetized mice, the bladder capacity was decreased ~fourfold when cystometry was performed acutely after surgical implantation of a suprapubic catheter. Our findings provide a paradigm for the noninvasive, in vivo monitoring of a hollow organ in behaving animals and pinpoint important limitations of the current gold standard techniques to study the LUT in mice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553215 | PMC |
http://dx.doi.org/10.7554/eLife.79378 | DOI Listing |
JACC Case Rep
January 2025
Interventional Cardiology Section, Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA.
Aneurysms of the interventricular membranous septum are a rare anatomical feature that can be detected incidentally on computed tomography or echocardiography. Such aneurysms can pose challenges in the treatment of patients with aortic valve stenosis. A case series of 2 patients with membranous septal aneurysms treated successfully with current-generation balloon-expandable and self-expanding transcatheter heart valves is presented here.
View Article and Find Full Text PDFSurg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedics, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
Purpose: Previous studies reported that anterior knee pain (AKP) occurs with an incidence of 32% after opening-wedge high tibial osteotomy (OWHTO). However, the biomechanical effects of this procedure on patellofemoral joints (PFJs) remain unclear. We aimed to quantify the changes in the kinematics and cartilage conditions of the PFJ during stair climbing before and after OWHTO.
View Article and Find Full Text PDFEur J Med Res
January 2025
Clinical Research and Big Data Center, South China Research Center for Acupuncture and Moxibustion, Medical College of Acu-Moxi and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China.
Objectives: Poststroke dysphagia (PSD) is a common complication after stroke but there is limited information on its global prevalence and influencing factors, such as spatial, temporal, demographic characteristics, and stroke-related factors. Our study seeks to fill this knowledge gap by exploring the overall prevalence of PSD and its influencing factors.
Methods: A search of English-language literature from database inception from 2005 until May 2022 was performed using PubMed, Embase, Web of Science, Cochrane Library, and Scopus.
Medicine (Baltimore)
November 2024
Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi Province, China.
Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.
Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!