Article Abstract

We describe fractionation of sub-micron vesicles and particles suspended in high conductivity electrolytes using an electrokinetically biased Deterministic Lateral Displacement (DLD) device. An optimised, asymmetric array of micron-sized pillars and gaps, with an AC electric field applied orthogonal to the fluid flow gives an approximately ten-fold reduction in the intrinsic critical diameter () of the device. The asymmetry in the device maximises the throughput. Fractionation of populations of 100 nm and 400 nm extruded vesicles is achieved in 690 mS m KCl, and 100 nm, 200 nm and 500 nm polystyrene particles in 105 mS m KCl. The electrokinetically biased DLD may provide solutions for simple and rapid isolation of extracellular vesicles.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2lc00583bDOI Listing

Publication Analysis

Top Keywords

deterministic lateral
8
lateral displacement
8
electrokinetically biased
8
electrokinetic deterministic
4
displacement fractionation
4
vesicles
4
fractionation vesicles
4
vesicles nano-particles
4
nano-particles describe
4
describe fractionation
4

Similar Publications

Despite being a high-resolution separation technique, deterministic lateral displacement (DLD) technology is facing multiple challenges with regard to design, manufacture, and operation of pertinent devices. This work specifically aims at alleviating difficulties associated with design and manufacture of DLD chips. The process of design and production of computer-aided design (CAD) mask layout files that are typically required for computational modeling analysis, optimization, as well as for manufacturing DLD-based micro/nanofluidic chips is complex, time-consuming, and often necessitates a high level of expertise in the field.

View Article and Find Full Text PDF

Resolving and routing magnetic polymorphs in a 2D layered antiferromagnet.

Nat Mater

January 2025

State Key Laboratory of Surface Physics, Key Laboratory of Micro and Nano Photonic Structures (MOE), and Department of Physics, Fudan University, Shanghai, China.

Polymorphism, commonly denoting diverse molecular or crystal structures, is crucial in the natural sciences. In van der Waals antiferromagnets, a new type of magnetic polymorphism arises, presenting multiple layer-selective magnetic structures with identical total magnetization. However, resolving and manipulating such magnetic polymorphs remain challenging.

View Article and Find Full Text PDF

Circulating tumor cells (CTCs) have served as noninvasive tumor biomarkers in many types of cancer. Here, we detected CTCs in mediastinal neuroblastoma (mNB) patients for use as diagnostic and treatment response predictive biomarkers. We employed a cascaded filter deterministic lateral displacement microfluidic chip (CFD-Chip) to enrich CTCs in peripheral blood from 32 mNB patients and 7 healthy children.

View Article and Find Full Text PDF

Myoblasts are defined as stem cells containing skeletal muscle cell precursors. However, there are some challenges associated with the purification of myoblast samples, including long culture times and ease of bacterial contamination. In this study, we propose a microfluidic myoblast cell enrichment and purification platform based on the principle of deterministic lateral displacement (DLD).

View Article and Find Full Text PDF

Unified translation of medical images from one-to-many distinct modalities is desirable in healthcare settings. A ubiquitous approach for bilateral medical scan translation is one-to-one mapping with GANs. However, its efficacy in encapsulating diversity in a pool of medical scans and performing one-to-many translation is questionable.

View Article and Find Full Text PDF