A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

People at a persistent pain service can walk it, but some struggle to talk about it: Reliability, detectable difference and clinically important difference of the six-minute walk test. | LitMetric

Objectives: The six-minute walk test (6MWT) is a commonly used measure of functional capacity. This study is the first to investigate the test-retest reliability, minimal detectable difference (MDD) and the minimal clinically important difference (MCID) for people attending a persistent pain service. Relationships between change in 6MWT performance and change in self-reported physical, functional and psychological outcome measures were also explored.

Methods: A cross-sectional repeated measures design was used with people having >9 months of pain attending an 8-week outpatient persistent pain programme. For reliability and MDD, 27 people were recruited, for MCID calculations, 32 people were recruited. The MCID was examined by dichotomising people into "improvers", or "non-improvers" based upon the Global Rating of Change (GRC) in physical abilities score.

Results: The mean (SD) 6MWT distance was 389.4 (93.6) m at programme start, and 427.8 (83.0) m at week eight completion. The test-retest reliability was good (intraclass correlation coefficient = 0.89) and the MDD = 86.1 m. As there was no relationship between change in 6MWT distance and GRC physical abilities at week eight (r = 0.132, p = 0.472) the MCID could not be calculated. Furthermore, no relationships were found between change in 6MWT distance and other self-reported measures. Changes in GRC physical abilities and 6MWT were frequently discordant, with increased 6MWT for 7/11 "GRC non-improvers" and decreased 6MWT for 7/21 "GRC improvers".

Conclusions: Amongst this cohort, change in physical ability may or may not be reflected by self-reported change. Objective tests of physical ability are recommended for people attending pain services, and validated tests should align with intervention aims.

Download full-text PDF

Source
http://dx.doi.org/10.1002/msc.1687DOI Listing

Publication Analysis

Top Keywords

persistent pain
12
change 6mwt
12
grc physical
12
physical abilities
12
6mwt distance
12
pain service
8
detectable difference
8
clinically difference
8
six-minute walk
8
walk test
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!