Phages are uniquely suited for bacterial detection due to their low cost and ability to recognize live bacteria. Herein, our work establishes the proof-of-concept detection of Salmonella in orange juice based on a phage-mediated portable magnetic relaxation switching (MRS) biosensor. The limit of quantification (LOQ) could reach 5 CFU/mL (95 % confidence interval [CI]: 4-7, N = 4) with a linear range of 10-10 CFU/mL, which has improved 10-fold than that without bioorthogonal signal amplification. The recovery rate of the phage-based MRS biosensor was 95.0 % (95 % confidence interval [CI]: 89.0 %-100.9 %, N = 6). The specificity of the phage-based MRS biosensor was 100 % without false-positive results. In addition, this sensor was able to detect <10 CFU per 25 mL of Salmonella in orange juice with 4-h pre-enrichment. The result from the phage-based MRS biosensor is consistent with that from the standard plate count method. This sensor provides a reliable and ultrasensitive detection platform for pathogens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2022.134035DOI Listing

Publication Analysis

Top Keywords

magnetic relaxation
8
relaxation switching
8
switching biosensor
8
signal amplification
8
95 % confidence
8
confidence interval
8
interval [ci]
8
phage-based biosensor
8
phage-based magnetic
4
biosensor
4

Similar Publications

Single-molecule Magnet Properties of Silole- and Stannole-ligated Erbium Cyclo-octatetraenyl Sandwich Complexes.

Chemistry

January 2025

University of Sussex, Department of Chemistry, School of Life Sciences, BN1 9QJ, Brighton, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.

The synthesis, structures and magnetic properties of an η5-silole complex and an η5-stannole complex of erbium are reported. The sandwich complex anions [(η5-CpSi)Er(η8-COT)]- and [(η5-CpSn)Er(η8-COT)]-, where CpSi is [SiC4-2,5-(SiMe3)2-3,4-Ph2]2- (1Si), CpSn is [SnC4-2,5-(SiMe3)2-3,4-Me2]2- (1Sn) and COT = cyclo-octatetraenyl, were obtained as their [K(2.2.

View Article and Find Full Text PDF

Tendon disease ranks among the leading reasons patients consult their general practitioners, comprising approximately one-third of musculoskeletal appointments. Magnetic resonance imaging (MRI) is regarded as the gold standard for assessing tendons. Due to their short transverse relaxation time (T2), Tendons show up as a signal void in conventional MRI scans, which employ sequences with echo times (TEs) around several milliseconds.

View Article and Find Full Text PDF

We investigated the extracellular and intracellular digestion of bivalves employing magnetic resonance imaging (MRI). Ruditapes philippinarum clams and Mytilus galloprovincialis mussels were incubated in seawater containing a contrast reagent (GdDTPA) at 20°C. The digestive systems, from the esophagus to the rectum, were visualized at a high signal intensity by the T1-weighted MRI.

View Article and Find Full Text PDF

Loz1 is a zinc-responsive transcription factor in fission yeast that maintains cellular zinc homeostasis by repressing the expression of genes required for zinc uptake in high zinc conditions. Previous deletion analysis of Loz1 found a region containing two tandem CH zinc-fingers and an upstream "accessory domain" rich in histidine, lysine, and arginine residues to be sufficient for zinc-dependent DNA binding and gene repression. Here we report unexpected biophysical properties of this pair of seemingly classical CH zinc fingers.

View Article and Find Full Text PDF

Normal variations of myocardial T1, T2 and T2* values at 1.5 T cardiac MRI in sex-matched healthy volunteers.

Diagn Interv Imaging

January 2025

UFR Santé INSERM U1096, Rouen 76183, France; Department of Radiology and Medical Imaging (Cardiac Imaging Unit), CHU de Rouen Normandie, Hôpital Charles Nicolle, University of Rouen Normandie, Rouen 76000, France. Electronic address:

Purpose: The purpose of this study was to determine the normal variations of myocardial T1, T2, and T2* relaxation times on cardiac MRI obtained at 1.5 T in healthy, sex-balanced volunteers aged between 18 and 69 years.

Material And Methods: A total of 172 healthy volunteers were recruited prospectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!