This study investigates the symmetry change in joint angle and joint moment of knee joints following a Running-Induced Fatigue counter movement Jump. Twelve amateur runners volunteered to participate in the study. A prolonged running protocol was used to induce fatigue. Joint angle and moment were recorded during the push and flexion phase of the CMJ before and immediately after fatigue. Borg scale (RPE>17) and real-time heart rate monitoring (HR>90%HRmax) were used to confirm running fatigue. Symmetry function (SF) was used to assess the symmetry of the knee Angle and moment variation parameters over the entire push-off and landing phases based on time series analysis. Paired sample -test was used to examine changes in SF before and after acute fatigue. The Angle and moment of the knee are asymmetrical in all planes (SF > 0.05), with SF ranging from 5 to 130% in angle and 5-110% in moment. There was a significant increase in knee joint angle asymmetry in the horizontal plane during the push-off and landing stage following the prolonged - Running Protocol implementation. These increases in asymmetry are mainly caused by excessive external rotation of the dominant knee joint. These findings indicate that fatigue-induced changes during CMJ may progress knee movement pattern asymmetry in the horizontal plane.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9428587PMC
http://dx.doi.org/10.3389/fphys.2022.877394DOI Listing

Publication Analysis

Top Keywords

knee joint
12
joint angle
12
angle moment
12
time series
8
series analysis
8
running fatigue
8
moment knee
8
prolonged running
8
running protocol
8
push-off landing
8

Similar Publications

Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.

Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.

View Article and Find Full Text PDF

Introduction: Two-stage revision is considered the gold standard treatment in chronic periprosthetic joint infection (PJI) but no specific criteria or examination exist to determine infection eradication before reimplantation. This study aimed to assess the diagnostic performance of leukocyte scintigraphy after the first-stage procedure in two-stage revision for chronic PJI.

Material And Methods: Patients studied with leukocyte scintigraphy after cement spacer insertion for knee PJI from January 2012 to December 2021 were retrospectively included.

View Article and Find Full Text PDF

Tibial plateau fracture is a fracture involving the proximal articular surface of the tibia, and its injury mechanism is complex, the fracture morphology is different, and it is often accompanied by different degrees of soft tissue injury, which is difficult to diagnose and treat. In recent years, the research hotspot has focused on solving the reduction and fixation of the posterior lateral column of the tibial plateau, because it has been clinically found that the residual sagittal plane after tibial plateau fracture is insufficient reduction or loss of reduction leads to knee joint dysfunction. The posterior inclination angle of the tibial plateau is an important parameter to describe the sagittal alignment of the tibia.

View Article and Find Full Text PDF

Objective: To investigate the clinical utility of novel of new hematological markers in the preoperative diagnosis of periprosthetic joint infection (PJI).

Methods: A retrospective analysis was conducted on a total of 149 patients who underwent revision of total hip arthroplasty (THA) or total knee arthroplasty (TKA) at a single center between January 2016 and June 2022, including 63 males and 86 females, aged from 47 to 93 years old with an average of (69.5±11.

View Article and Find Full Text PDF

Objective: To analyze the effectiveness of three internal fixation methods, namely hollow screw combined with Kirschner wire tension band, hollow screw combined with anchor nail, and modified 1/3 tubular steel plate, in the treatment of avulsion fracture of tibial tubercle (AFTT) in adolescents.

Methods: Between January 2018 and September 2023, 19 adolescent AFTT patients who met the selection criteria were admitted. According to different internal fixation methods, patients were divided into group A (8 cases, hollow screw combined with Kirschner wire tension band), group B (6 cases, hollow screw combined with anchor nail), and group C (5 cases, modified 1/3 tubular steel plate).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!