Objective: We investigated possible gender differences for hepatic fibrosis in extracardiac-Fontan patients.

Methods: We identified extracardiac Fontan, performed between 2000 and 2016, who underwent cardiac catheterizations with transvenous hepatic biopsies between April 2012 and June 2022. We divided the patients by gender for analysis.

Results: We identified 116 patients who underwent 145 transvenous biopsies, with 29 patients undergoing 2 biopsies at an average interval of 5 ± 1 years. We divided the 145 biopsies into two groups: 1) 98/145 (68%) males and 2) 47/145 (32%) females. For the 47 female liver biopsy specimens, the median total fibrosis score was 3 (0-8), and for the 98 male liver biopsy specimens, the median total fibrosis score was 2 (0-6), p = .007. The average age at surgery for females was 3 ± 1 years and for males 3 ± 1 years, p = .99. Average Fontan duration at biopsy for females was 11 ± 5 years and for males, 10 ± 4 years, p = .23. No other demographic, anatomic, echocardiographic, laboratory, or hemodynamic findings demonstrated statistically significant gender differences.

Conclusions: Females had statistically significantly higher median total fibrosis scores than males for the similar average age at extracardiac Fontan and average Fontan duration.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocs.16880DOI Listing

Publication Analysis

Top Keywords

extracardiac fontan
12
median total
12
total fibrosis
12
hepatic fibrosis
8
gender differences
8
liver biopsy
8
biopsy specimens
8
specimens median
8
fibrosis score
8
average age
8

Similar Publications

Mixed reality for preoperative planning and intraoperative assistance of surgical correction of complex congenital heart defects.

J Thorac Cardiovasc Surg

January 2025

Division of Cardiology, The Hospital for Sick Children, Toronto, ON, Canada; Center for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, ON, Canada.

Objectives: Mixed reality (MixR) is an innovative visualization tool that presents virtual elements in a real-world environment, enabling real-time interaction between the user and the combined digital/physical reality. We aimed to explore the feasibility of MixR in enhancing preoperative planning and intraoperative guidance for the correction of various complex congenital heart defects (CHDs).

Methods: Patients underwent cardiac computed tomography or cardiac magnetic resonance and segmentation of digital imaging and communications in medicine (DICOM) images was performed.

View Article and Find Full Text PDF

Background: Children with one functional ventricle might receive the Fontan procedure as palliative management to prolong their lives. However, the heart remains functionally univentricular, which may result in disrupted absorption of nutrients, including Vitamin D. Individuals with Fontan circulation have limited physical activity and sun exposure, which might further contribute to Vitamin D deficiency.

View Article and Find Full Text PDF

Background: The discussion of Fontan fenestration is difficult because many institutions have different strategies over time. In our institute, we performed a non-fenestrated Fontan procedure for single-ventricular physiology as our definitive strategy.

Methods: Between August 1999 and December 2007, 72 consecutive patients with single-ventricle physiology underwent extracardiac total cavopulmonary connection without fenestration as our definitive strategy.

View Article and Find Full Text PDF

T1 relaxation time quantification on parametric maps is routinely used in cardiac imaging and may serve as a non-invasive biomarker for diffuse liver disease. In this study, we aimed to investigate the relationship between liver T1 values and cardiac function in patients with congenital heart disease (CHD) and compared patients with a biventricular circulation (BVC) to those with a Fontan circulation (FC). Magnetic resonance images from patients with CHD, obtained between June and December 2023 on a 1.

View Article and Find Full Text PDF

Long-term outcomes of extracardiac Gore-Tex conduits in Fontan patients.

Int J Cardiol Congenit Heart Dis

June 2024

Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.

Background: Extracardiac conduit Fontan procedure (ECFP) employing a Gore-Tex conduit has been widely used for patients with single ventricle physiology; however, the long-term status of the conduit is unknown. We investigated the changes in a Gore-Tex conduit after ECFP and the factors associated with its narrowing.

Methods: We conducted a retrospective analysis of 86 patients who underwent ECFP between January 1995 and December 2008 and had cardiac computed tomography (CT) during the follow-up period.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!