Purpose: Continuous positive airway pressure (CPAP) ventilation hyperinflates the lungs and reduces diaphragmatic motion. We hypothesized that CPAP could be safely combined with deep inspiratory breath hold (CPAP-DIBH) during lung stereotactic radiotherapy (SBRT).
Material And Methods: Patients with stage-1 lung cancer or lung metastasis treated with CPAP-DIBH SBRT between 3/2017-5/2021 were analyzed retrospectively. Patient characteristics, treatment parameters, duration of breath holds in all sessions and tolerance to CPAP-DIBH were recorded. Local control (LC) was assessed from CT or PET-CT imaging. The distances between the tumor and mediastinal organs at risk (OAR) in centrally located tumors using either free breathing (FB) or CPAP-DIBH were compared. Toxicity was graded retrospectively.
Results: Forty-five patients with 71 lesions were treated with CPAP-DIBH SBRT. Indications for CPAP-DIBH were prior radiation (35/71, 65%), lower lobe location (34/71, 48%), multiple lesions (26/71, 36.6%) and proximity to mediastinal OAR (7/71, 10%). Patient characteristics were: F:M 43%: 57%; mean gross tumor volume 4.5cm (SD 7.9), mean planning target volume 20cm (SD 27), primary: metastatic lesions (7%:93%). Mean radiation dose was 52.5 Gray (SD3.5). Mean lung volume was 5292cm (SD 1106). Mean duration of CPAP-DIBH was 41.3s (IQR 31-46.8). LC at 2 years was 89.5% (95% CI 76-95.5). In patients with central lesions, the distance between the tumor and mediastinal OAR increased from 0.84cm (SD 0.65) with FB to 1.23cm (SD 0.8) with CPAP-DIBH (p=0.002). Most patients tolerated CPAP well and completed all treatments after starting therapy. Three patients did not receive treatment: 2 were unable to tolerate CPAP and 1 had syncope (pre-existing). Toxicity was grade 2 in 4/65 (6%) and grade 3 in 1/65 (1.5%). There was no grade 2 or higher esophageal or tracheal toxicities.
Conclusion: CPAP-DIBH assisted lung SBRT was tolerated well and was associated with minimal toxicity and favorable LC. This technique may be considered when treating multiple lung lesions, lesions located in the lower lobes or adjacent to mediastinal OAR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.canrad.2022.05.001 | DOI Listing |
Acta Oncol
February 2024
Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden; Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
Purpose/background: The aim of this study was to evaluate pencil beam scanning (PBS) proton therapy (PT) in deep inspiration breath-hold (DIBH) for mediastinal lymphoma patients, by retrospectively evaluating plan robustness to the clinical target volume (CTV) and organs at risk (OARs) on repeated CT images acquired throughout treatment. Methods: Sixteen mediastinal lymphoma patients treated with PBS-PT in DIBH were included. Treatment plans (TPs) were robustly optimized on the CTV (7 mm/4.
View Article and Find Full Text PDFClin Transl Radiat Oncol
March 2024
Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
Background: MRI-guidance may aid better discrimination between Organs at Risk (OARs) and target volumes in proximity of the mediastinum. We report the first clinical experiences with Stereotactic Body Radiotherapy (SBRT) of (ultra)central lung tumours on a 1.5 T MR-linac.
View Article and Find Full Text PDFCancers (Basel)
February 2024
Department of Radiation Oncology, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai 410210, India.
Adv Radiat Oncol
March 2024
Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland.
Purpose: Breath-hold (BH) technique can mitigate target motion, minimize target margins, reduce normal tissue doses, and lower the effect of interplay effects with intensity-modulated proton therapy (IMPT). This study presents dosimetric comparisons between BH and nonbreath-hold (non-BH) IMPT plans and investigates the reproducibility of BH plans using frequent quality assurance (QA) computed tomography scans (CT).
Methods And Materials: Data from 77 consecutive patients with liver (n = 32), mediastinal/lung (n = 21), nonliver upper abdomen (n = 20), and malignancies in the gastroesophageal junction (n = 4), that were treated with a BH spirometry system (SDX) were evaluated.
Radiother Oncol
January 2024
Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA. Electronic address:
Background/purpose: Central/ultra-central thoracic tumors are challenging to treat with stereotactic radiotherapy due potential high-grade toxicity. Stereotactic MR-guided adaptive radiation therapy (SMART) may improve the therapeutic window through motion control with breath-hold gating and real-time MR-imaging as well as the option for daily online adaptive replanning to account for changes in target and/or organ-at-risk (OAR) location.
Materials/methods: 26 central (19 ultra-central) thoracic oligoprogressive/oligometastatic tumors treated with isotoxic (OAR constraints-driven) 5-fraction SMART (median 50 Gy, range 35-60) between 10/2019-10/2022 were reviewed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!