AI Article Synopsis

  • The review focuses on two key methods: SSP-SIR, which targets TMS-related muscle artifact rejection, and SOUND, which aims to suppress general noise in EEG and MEG data, outlining theoretical backgrounds and practical applications for both.
  • It highlights the importance of objectively evaluating the effectiveness of these noise-cleaning methods while acknowledging their impact on the original signals, and discusses how findings can generalize beyond TMS-EEG to other EEG/MEG contexts.

Article Abstract

Neuronal electroencephalography (EEG) signals arise from the cortical postsynaptic currents. Due to the conductive properties of the head, these neuronal sources produce relatively smeared spatial patterns in EEG. We can model these topographies to deduce which signals reflect genuine TMS-evoked cortical activity and which data components are merely noise and artifacts. This review will concentrate on two source-based artifact-rejection techniques developed for TMS-EEG data analysis, signal-space-projection-source-informed reconstruction (SSP-SIR), and the source-estimate-utilizing noise-discarding algorithm (SOUND). The former method was designed for rejecting TMS-evoked muscle artifacts, while the latter was developed to suppress noise signals from EEG and magnetoencephalography (MEG) in general. We shall cover the theoretical background for both methods, but most importantly, we will describe some essential practical perspectives for using these techniques effectively. We demonstrate and explain what approaches produce the most reliable inverse estimates after cleaning the data or how to perform non-biased comparisons between cleaned datasets. All noise-cleaning algorithms compromise the signals of interest to a degree. We elaborate on how the source-based methods allow objective quantification of the overcorrection. Finally, we consider possible future directions. While this article concentrates on TMS-EEG data analysis, many theoretical and practical aspects, presented here, can be readily applied in other EEG/MEG applications. Overall, the source-based cleaning methods provide a valuable set of TMS-EEG preprocessing tools. We can objectively evaluate their performance regarding possible overcorrection. Furthermore, the overcorrection can always be taken into account to compare cleaned datasets reliably. The described methods are based on current electrophysiological and anatomical understanding of the head and the EEG generators; strong assumptions of the statistical properties of the noise and artifact signals, such as independence, are not needed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2022.109693DOI Listing

Publication Analysis

Top Keywords

source-based artifact-rejection
8
artifact-rejection techniques
8
tms-eeg data
8
data analysis
8
cleaned datasets
8
signals
5
source-based
4
tms-eeg
4
techniques tms-eeg
4
tms-eeg neuronal
4

Similar Publications

Neuronal electroencephalography (EEG) signals arise from the cortical postsynaptic currents. Due to the conductive properties of the head, these neuronal sources produce relatively smeared spatial patterns in EEG. We can model these topographies to deduce which signals reflect genuine TMS-evoked cortical activity and which data components are merely noise and artifacts.

View Article and Find Full Text PDF

Source-based artifact-rejection techniques available in TESA, an open-source TMS-EEG toolbox.

Brain Stimul

July 2020

The Turner Institute for Brain and Mental Health, School of Psychological Sciences, Monash Biomedical Imaging, Monash University, Victoria, 3168, Australia; Hopwood Centre for Neurobiology, Lifelong Health Theme, South Australian Health and Medical Research Institute (SAHMRI), P.O. Box 11060, Adelaide, 5001, Australia; Discipline of Psychiatry, Adelaide Medical School, University of Adelaide, Adelaide Health and Medical Sciences Building, Corner of North Terrace & George Street, Adelaide, 5000, Australia.

View Article and Find Full Text PDF

Data processing techniques in electroencephalography (EEG) and magnetoencephalography (MEG) need user interactions. However, particularly in clinical applications, fast and objective data processing is important. Here we present an observer-independent method for EEG and MEG analysis of mismatch negativity (MMN) that allows reliable estimation of source activity based on objective anatomical references.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!