Objective: The aim of this study was to radiographically compare cage subsidence and displacement between L5-S1 lateral anterior lumbar interbody fusion (ALIF) cages secured with an anterior buttress plate and cages secured with integrated screws.

Methods: Consecutive patients who underwent L5-S1 lateral ALIF with supplemental posterior fixation by a single surgeon from June 2016 to January 2021 were reviewed. Radiographs were analyzed and compared between the two groups based on the type of fixation used to secure the L5-S1 lateral ALIF cage: 1) anterior buttress plate or 2) integrated screws. The following measurements at L5-S1 were analyzed on radiographs obtained preoperatively, before discharge, and at latest follow-up: 1) anterior disc height, 2) posterior disc height, and 3) segmental lordosis. Cage subsidence and anterior cage displacement were determined radiographically.

Results: One hundred thirty-nine patients (mean age 60.0 ± 14.3 years) were included for analysis. Sixty-eight patients were treated with an anterior buttress plate (mean follow-up 12 ± 5 months), and 71 were treated with integrated screws (mean follow-up 9 ± 3 months). Mean age, sex distribution, preoperative L5-S1 lordosis, preoperative L5-S1 anterior disc height, and preoperative L5-S1 posterior disc height were statistically similar between the two groups. After surgery, the segmental L5-S1 lordosis and L5-S1 anterior disc heights significantly improved for both groups, and each respective measurement was similar between the groups at final follow-up. Posterior disc heights significantly increased after surgery with integrated screws but not with the anterior buttress plate. As such, posterior disc heights were significantly greater at final follow-up for integrated screws. Compared with patients who received integrated screws, significantly more patients who received the anterior buttress plate had cage subsidence cranially through the L5 endplate (20.6% vs 2.8%, p < 0.01), cage subsidence caudally through the S1 endplate (27.9% vs 0%, p < 0.01), and anterior cage displacement (22.1% vs 0%, p < 0.01).

Conclusions: In this radiographic analysis of 139 patients who underwent lateral L5-S1 ALIF supplemented by posterior fixation, L5-S1 cages secured with an anterior buttress plate demonstrated significantly higher rates of cage subsidence and anterior cage displacement compared with cages secured with integrated screws. While the more durable stability afforded by cages secured with integrated screws suggests that they may be a more viable fixation strategy for L5-S1 lateral ALIFs, there are multiple factors that can contribute to cage subsidence, and, thus, definitive presumption cannot be made that the findings of this study are directly related to the buttress plate.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2022.7.SPINE22436DOI Listing

Publication Analysis

Top Keywords

integrated screws
32
cage subsidence
28
buttress plate
28
anterior buttress
24
l5-s1 lateral
20
cages secured
20
disc height
16
posterior disc
16
anterior
15
l5-s1
13

Similar Publications

Pseudotunnel Magnetoresistance in Twisted van der Waals FeGeTe Homojunctions.

Adv Mater

January 2025

Faculty of Science and Engineering, Aoyama Gakuin University, 5-10-1 Fuchinobe, Sagamihara, Kanagawa, 252-5258, Japan.

Twistronics, a novel engineering approach involving the alignment of van der Waals (vdW) integrated two-dimensional materials at specific angles, has recently attracted significant attention. Novel nontrivial phenomena have been demonstrated in twisted vdW junctions (the so-called magic angle), such as unconventional superconductivity, topological phases, and magnetism. However, there have been only few reports on integrated vdW layers with large twist angles θ, such as twisted interfacial Josephson junctions using high-temperature superconductors.

View Article and Find Full Text PDF

Purpose: Bone cement-reinforced fenestrated pedicle screws (FPSs) have been widely used in the internal fixation and repair of the spine with osteoporosis in recent years and show significant improvement in fixation strength and stability. However, compared with conventional reinforcement methods, the advantages of bone cement-reinforced FPSs remain undetermined. This article compares the effects of fenestrated and conventional pedicle screws (CPSs) combined with bone cement in the treatment of osteoporosis.

View Article and Find Full Text PDF

Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.

Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.

View Article and Find Full Text PDF

Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.

Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.

View Article and Find Full Text PDF

Dental implants are commonly employed to address edentulism, while orthodontic treatments often incorporate mini-screws to enhance tooth movement and provide stable anchorage. Both procedures are integral to modern dental practice and frequently interact in comprehensive care scenarios. While oral health professionals routinely assess patients' medical histories before procedures, undiagnosed coagulopathies, such as Von Willebrand Disease (VWD), can present significant challenges when invasive procedures are carried out, such as the insertion of implants or mini-implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!