Aims: The prognostic implication of left ventricular (LV) torsion on ST-elevation myocardial infarction (STEMI) is unclear.

Methods And Results: We analysed cardiovascular magnetic resonance (CMR) findings of 420 patients from a registry study (NCT03768453). These patients received CMR examination within 1 week after timely primary percutaneous coronary intervention. LV torsion and other CMR indexes were measured. Compared with healthy control subjects, STEMI significantly decreased patients' LV torsion (1.04 vs. 1.63°/cm, P < 0.001). During follow-up (median, 52 months), the reduction of LV torsion was greater in patients with than without composite major adverse cardiac and cerebrovascular events (MACCEs, 0.79 vs. 1.08°/cm, P < 0.001). The risk of MACCEs would increase to 1.125- or 1.092-fold, and the risk of 1-year LV remodelling would increase to 1.110- or 1.082-fold for every 0.1°/cm reduction in LV torsion after adjustment for clinical or CMR parameters respectively. When divided dichotomously, patients with LV torsion≤ 0.802°/cm had significantly higher risk of MACCEs (40.2 vs. 12.3%, P < 0.001) and more remarkable LV remodelling (46.1 vs. 11.9%, P < 0.001) than patients with better LV torsion. The addition of LV torsion to conventional prognostic factors such as the LV ejection fraction and infarction size led to a better risk classification model of patients for both MACCEs and LV remodelling. Finally, tobacco use, worse post-PCI flow, and greater microvascular obstruction size were presumptive risk factors for reduced LV torsion.

Conclusion: LV torsion measured by CMR is closely associated with the prognosis of STEMI and would be a promising indicator to improve patients' risk stratification.

Clinical Trial Registration: Clinicaltrials.gov, NCT03768453.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ehjci/jeac177DOI Listing

Publication Analysis

Top Keywords

torsion
9
left ventricular
8
ventricular torsion
8
torsion measured
8
magnetic resonance
8
st-elevation myocardial
8
myocardial infarction
8
reduction torsion
8
risk macces
8
patients
7

Similar Publications

We report nonadiabatic dynamics computations on CH initiated on a coherent superposition of the five lowest cationic states, employing the Quantum Ehrenfest method. In addition to the totally symmetric carbon-carbon double bond stretch and carbon-hydrogen stretches, we see that the three non-totally symmetric modes become stimulated; torsion and three different CH stretching patterns. Thus, a coherent superposition of states, of the type involved in an attochemistry experiment, leads to the stimulation of specific non-totally symmetric motions.

View Article and Find Full Text PDF

In this paper, we demonstrate that torsional surface elastic waves can propagate along the curved surface of a metamaterial elastic rod (cylinder) embedded in a conventional elastic medium. The crucial parameter of the metamaterial rod is its elastic compliance s44(1)ω, which varies as a function of frequency ω analogously to the dielectric function εω in Drude's model of metals. As a consequence, the elastic compliance s44(1)ω can take negative values s44(1)ω<0 as a function of frequency ω.

View Article and Find Full Text PDF

Thoracic point-of-care ultrasound (T-POCUS) has grown in popularity and usage in small animal emergencies and critical care settings due to its non-invasive nature, mobility, and ability to acquire images in real time. This review summarizes current understanding about T-POCUS in dogs and cats with respiratory illnesses, including normal thoracic ultrasonography appearance and numerous pathological situations. The basics of T-POCUS are covered, including equipment, scanning procedures, and picture settings.

View Article and Find Full Text PDF

Toward improved auricle reconstruction: The role of FDM 3D printing with PCL and TPU materials.

Biomater Adv

January 2025

Department of Chemistry, Materials and Chemical Engineering G. Natta, Politecnico di Milano, Piazza Leonardo Da Vinci 32, Milan, Italy; Local Unit Politecnico di Milano, Milan, Italy. Electronic address:

Microtia, along with trauma, represents one of the main causes of external ear malformation. Different clinical techniques were developed for the reconstruction of the auricle, but they all have some drawbacks. This work is focused on the development of an innovative 3D porous scaffold, printed by Fused Deposition Modelling (FDM) and based on laser-scanned images of the healthy contralateral ear of the patient.

View Article and Find Full Text PDF

Objectives: To evaluate the value of contrast-enhanced CT in diagnosing ultrasonography-unspecified adnexal torsion (AT).

Methods: Surgically confirmed patients with painful pelvic masses (n = 165) were retrospectively collected from two institutes. Two senior radiologists independently reviewed the CT images and determined the Hounsfield unit difference between non-contrast vs portal venous phases (ΔHU) in both derivation and validation samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!