Anterior segment parameters on optical coherence tomography in healthy South Asian children.

Photodiagnosis Photodyn Ther

Department of Ophthalmology, Foundation University Islamabad/Foundation University Medical College and Fauji Foundation Hospital, Defence Avenue DHA Phase-1, Islamabad 44000, Pakistan. Electronic address:

Published: December 2022

Purpose: High resolution spectral domain optical coherence tomography (SD-OCT) was used to assess the anterior segment structure parameters in healthy South Asian children.

Methods: 108 eyes of 54 healthy children ≤ 16 years were recruited after a thorough eye exam. The anterior segment analysis was be done by Optopol Revo 80 high resolution SD-OCT. Central corneal thickness (CCT), Angle opening distance (AOD), Anterior chamber (AC) angle, Trabecular iris space area (TISA), Trabecular iris angle (TIA), iris thickness at 2 mm, internal AC diameter and lens vault were evaluated.

Results: Mean age was 11.38 years. Mean IOP was 13.63 mmHg, mean axial length, 22.82 mm, mean spherical equivalent, -0.14 D, mean CCT, 532.6 µm and mean CDR was 0.31. The mean internal AC diameter was 11609.15 µm. The nasal and temporal AC angles was 53.54° and 50.37°, respectively [P = .033]. The nasal and temporal AOD500 were 0.9 mm and 0.85 mm, respectively [P = .629]. The nasal and temporal AOD750 were 1.21 mm and 1.06 mm, respectively [P = .583]. The nasal TIA was 41.75°; the temporal TIA; 40.24° [P = .325]. The nasal TISA500 was 0.33 mm; the temporal TISA500, 0.31 mm [P = .012]. The nasal TISA750 was 0. 59 mm; the temporal TISA750, 0.56 mm [P = .746]. The nasal iris thickness at 2 mm was 483.54 µm; the temporal iris thickness, 505.8 µm [P = .273]. The mean lens vault was -519.58 µm.

Conclusions: Our study data depicts the normal anterior segment parameters in healthy Pakistani children.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pdpdt.2022.103101DOI Listing

Publication Analysis

Top Keywords

anterior segment
16
iris thickness
12
nasal temporal
12
segment parameters
8
optical coherence
8
coherence tomography
8
healthy south
8
south asian
8
high resolution
8
parameters healthy
8

Similar Publications

Background: A modified computed tomography angiography (CTA)-based Carotid Plaque Reporting and Data System (Plaque-RADS) classification was applied to a cohort of patients with embolic stroke of undetermined source to test whether high-risk Plaque-RADS subtypes are more prevalent on the ipsilateral side of stroke. With the widespread use of CTA for stroke evaluation, a CTA-based Plaque-RADS would be valuable for generalizability.

Methods: A retrospective observational cross-sectional study was conducted at a single integrated health system comprised of 3 hospitals with a comprehensive stroke center between October 1, 2015, and April 1, 2017.

View Article and Find Full Text PDF

Background: Taylor and Palmer introduced an angiosome (vascular) concept in reconstructive plastic surgery in 1987. The angiosome is considered a segment of a nerve (cranial or peripheral nerve) supplied by a primary source of blood vessels.

Purpose: To observe the arteries supplying the vestibulocochlear nerves (VIII) from the brainstem till their termination.

View Article and Find Full Text PDF

Both de Winter syndrome and Wellens syndrome mainly indicate severe stenosis in the proximal segment of the anterior descending coronary artery. However, as research deepens, the accuracy and specificity of diagnosing proximal left anterior descending coronary artery (LAD) culprit lesions separately by de Winter syndrome or Wellens syndrome are challenged. The patient in this case developed both syndromes in a short period of time, and imaging showed significant stenosis of the proximal LAD, indicating a culprit lesion.

View Article and Find Full Text PDF

The prevailing narrative in scientific literature has long overemphasized the role of ocular axes in intraocular lens (IOL) implantation, perpetuating misconceptions that have led to unnecessary exclusions of patients. Historical assumptions, coupled with inconsistent terminology and statistical inaccuracies, have muddled clinical decision-making. This review delves into these misconceptions, offering a critical reassessment of their relevance.

View Article and Find Full Text PDF

Objective: To observe the clinical outcomes of anterior approach for the revision surgery following unsuccessful bone cement augmentation in osteoporotic vertebral compression fractures.

Methods: A total of 10 patients who experienced unsuccessful bone cement augmentation underwent anterior revision surgery between January 2020 and December 2021. There were 2 males and 8 females.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!