Background: Treatment of aneurysmal type B aortic dissection often involves thoracic endovascular aortic repair (TEVAR). However, persistent patency of the false lumen from type R entry flow is common and is associated with late complications including rupture. We describe 9 patients with aneurysmal chronic type B aortic dissections and patent false lumens and 7 despite prior thoracic endovascular aortic repair. The goal of the false lumen intercostal embolization in these patients was to achieve propagation of false lumen thrombosis (FLT) and to prevent spinal cord ischemia (SCI) using a staged approach in the overall treatment of their complex aortic aneurysm.
Methods: A multicenter retrospective review was performed of all consecutive false lumen intercostal embolization procedures; 9 were identified. Preoperative and postoperative computed tomographic angiograms were compared. We hypothesized that embolization was a safe and feasible treatment option. The primary outcome was procedural characteristics and SCI to establish safety and feasibility. Secondary outcomes included a change in supraceliac patent false lumen length and other perioperative clinical outcomes.
Results: In total, 30 of 31 (97%) targeted false lumen intercostal arteries were successfully coiled. Median procedural time was 57 min (interquartile range [IQR] 23-99), median air kerma was 585 mGy (IQR 398-1,644), and median contrast dose was 141 mL (IQR 74-240). After embolization, all patients demonstrated propagation of FLT, with mean false lumen length decreasing by 48% from 13.8 cm to 6.6 cm. There was no mortality associated with this procedure; 2 patients suffered a lumbar drain-related complication; 1 with cerebrospinal fluid leak and 1 with a spinal hematoma that was managed conservatively with no neurological deficit. No other complications occurred.
Conclusions: In this review, false lumen intercostal coil embolization was technically feasible and did not result in any cases of SCI. The procedures required acceptable amounts of operative time, fluoroscopic dose, and contrast. All patients experienced propagation of FLT and no long-term procedure-related morbidity was noted. More data will be required to ascertain whether this procedure is effective at halting type R entry flow, preventing future type II entry flow, and promoting aortic remodeling over time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.avsg.2022.07.023 | DOI Listing |
Vascular
January 2025
Department of Surgery, Division of Vascular and Endovascular Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA.
Sci Rep
January 2025
Department of Cardiovascular Surgery, Nihon University Hospital, Itabashi-ku, Tokyo, Japan.
We investigated the influence of false lumen (FL) status on the systemic inflammatory response triggered by acute aortic dissection (AAD) using cytokine profiling. The study included 44 patients with AAD. Patients were divided between those with a thrombosed FL (Group T, n = 21) and those with a non-thrombosed FL (Group P, n = 23).
View Article and Find Full Text PDFRev Esp Cardiol (Engl Ed)
December 2024
Department of Cardiovascular Surgery, West China Hospital of Sichuan University, P.R. China. Electronic address:
In surgery for acute type A aortic dissection, controlling bleeding from the posterior wall of the proximal anastomosis is particularly challenging. To address this, we use the "reversed turn-up technique." For the reinforcement of the proximal aortic stump, Teflon felt strips were placed inside and outside the suture line with 4-0 polypropylene continuous transverse mattress sutures, and BioGlue was applied to the false lumen.
View Article and Find Full Text PDFMed Phys
December 2024
Department of Echocardiography, Ultrasound Diagnostic Center, The First Hospital of Jilin University, Changchun, China.
Background: Dialysis Access (DA) stenosis impacts hemodialysis efficiency and patient health, necessitating exams for early lesion detection. Ultrasound is widely used due to its non-invasive, cost-effective nature. Assessing all patients in large hemodialysis facilities strains resources and relies on operator expertise.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!