A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single-Center Experience with the Femoral-to-Brachial Preloaded Delivery System for Fenestrated-Branched Endovascular Repair of Complex Aortic Aneurysms. | LitMetric

Purpose: To assess technical aspects and outcomes of fenestrated-branched endovascular aortic repair (FB-EVAR) using a femoral-to-brachial (FTB) preloaded delivery system (PDS) with two separate configurations.

Methods: Clinical data of all consecutive patients enrolled in a prospective study to evaluate FB-EVAR for complex abdominal and thoracoabdominal aortic aneurysms (CAAAs & TAAA) between 2013 and 2020 were reviewed. Patients treated with FTB-PDS were included. The two configurations included 4 trans-brachial preloaded wires (4BR) or 2 trans-brachial and 2 transfemoral preloaded wires (2BR-2FE). Outcome measures included technical success, procedural metrics, 30-day or in-hospital mortality, major adverse events (MAEs), and target-vessel outcomes.

Results: There were 115 patients with a mean age of 73.8 ± 8 years, treated with FTB-PDS. Of these, 62 patients (54%) had 4BR and 53 patients (46%) had 2BR-2FE FTB-PDS. There were 106 TAAA (92%) and 9 CAAAs (8%). Technical success, defined as successful implantation of the stent-graft and all intended target-vessel stents without type I or III endoleak, was 97%, with no differences in total operating time, endovascular time, and radiation dose between groups. There were 3 deaths (3%) at 30 days. MAEs were noticed in 21 patients (18%) with no difference between groups, including new-onset dialysis (2% vs. 4%, P = 0.59), and paraplegia (7% vs. 11%, P = 0.51), for 4BR and 2BR-2FE, respectively. Patient survival and freedom from aortic-related mortality at 2-years were 79 ± 5% and 97 ± 1.7%, respectively, with no difference between groups.

Conclusion: The use of FTB-PDS for FB-EVAR is safe with high technical success and a reasonable rate of MAEs. Each configuration provides specific benefits based on patient anatomy, while having similar procedural metrics and clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-022-03252-6DOI Listing

Publication Analysis

Top Keywords

technical success
12
preloaded delivery
8
delivery system
8
fenestrated-branched endovascular
8
aortic aneurysms
8
treated ftb-pds
8
preloaded wires
8
procedural metrics
8
patients
6
single-center experience
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!