A high voltage with a very short duration and fast rising time is beneficial to generate uniform and diffuse plasma in dielectric barrier discharge (DBD) loads, and a power supply with a high power factor (PF) can reduce the impact on the power grid. According to two requirements, a unipolar high voltage pulsed power supply with power factor correction (PFC) is proposed in this paper. The power supply consists of a unipolar pulse high voltage generating unit, a PFC unit, and a driving circuit. By introducing a feedback clamping diode and a reverse current blocking diode in a flyback converter, repetitive nanosecond pulses are generated in the unipolar pulse high voltage generating unit. Because a discontinuous current mode strategy is adopted in the PFC unit and the driving signal is shared by the two units, a compact structure of the power supply is achieved, and a high PF is obtained. To validate the proposed pulsed power supply, an experimental setup is built for a DBD excimer lamp. The results show that the proposed power supply has the capability of not only providing a unipolar nanosecond pulse high voltage for the DBD excimer lamp but also achieving PF close to 1 and total harmonic distortion of less than 24%.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0089020DOI Listing

Publication Analysis

Top Keywords

power supply
28
high voltage
20
pulsed power
12
power factor
12
pulse high
12
power
11
high
8
supply high
8
high power
8
dielectric barrier
8

Similar Publications

Interfered by external factors, the receptive field limits the traditional CNN multispectral remote sensing building change detection method. It is difficult to obtain detailed building changes entirely, and redundant information is reused in the encoding stage, which reduces the feature representation and detection performance. To address these limitations, we design a Siamese network of shared attention aggregation to learn the detailed semantics of buildings in multispectral remote sensing images.

View Article and Find Full Text PDF

Water impact analysis due to coal-electricity generation using the life cycle assessment method: a case study in Malaysia.

Water Sci Technol

January 2025

Department of Engineering, School of Engineering and Technology, Sunway University, Bandar Sunway, Petaling, Jaya 47500, Malaysia.

Coal power plants adversely impact air pollution, but they also pose a risk to our water sources. Discharge wastewater from power plants may degrade the quality of nearby water bodies. This study evaluates the potential water-related environmental impacts of electricity generation at an ultra-supercritical coal power plant in Malaysia using the life cycle assessment method.

View Article and Find Full Text PDF

Wearable sensors have broad application potential in motion assessment, health monitoring, and medical diagnosis. However, relying on a specialized instrument for power supply and signal reading makes sensors unsuitable for on-site detection. To solve this problem, a reusable self-powered electrochromic sensor patch based on enzymatic biofuel cells were constructed to realize the on-site visualized monitoring.

View Article and Find Full Text PDF

Self-powered Biomedical Devices: biology, materials, and their interfaces.

Prog Biomed Eng (Bristol)

January 2025

East China University of Science and Technology, Interfacial Electrochemistry and Biomaterials, School of Materials Science and Engineering, Shanghai, 200237, CHINA.

Integrating biomedical electronic devices holds profound promise for advancements in healthcare and enhancing individuals' quality of life. However, the persistent challenges associated with the traditional batteries' limited lifespan and bulkiness hinder these devices' long-term functionality and consistent power supply. Here, we delve into the biology and material interfaces in self-powered medical devices by summarizing the intrinsic electric demands in humans, analyzing material and biological mechanisms for electricity generation and storage, and discussing the pathways toward self-chargeable powering.

View Article and Find Full Text PDF

This pilot study investigates distinctive features within the nail-enthesis complex among Psoriatic arthritis (PsA), Psoriasis (PSO), Rheumatoid Arthrit is (RA), and Healthy Control (HC) groups, utilizing a combined approach of ultrasound (US) and nailfold videocapillaroscopy (NVC). Clinical assessments and comprehensive US and NVC evaluations of the nail-enthesis complex were conducted on 72 subjects (18 PsA, 16 PSO, 19 RA, 19 HC). Unsupervised clustering models and factor analysis were employed to identify patterns and interrelationships between US and NVC parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!