We present a novel thin head atomic force microscope (AFM) that can be easily integrated with an upright optical microscope (OM). The optical beam detection unit in the AFM used an obliquely incident laser beam onto the cantilever, reducing the AFM head's effective thickness to 7.3 mm. That allows an open space above the cantilever probe to accommodate the objective lens up to 0.6 numerical aperture (N.A.) without obstruction. A multi-function digital controller was developed to control the AFM and reserved interfaces to communicate with the OM. To assess the performance of the developed AFM, we first measured the noise level and bandwidths of the AFM system. Then, the imaging quality of the AFM was evaluated by both calibration grids and two-dimensional materials. Finally, the thin head AFM was integrated into a homemade white light interferometer as a demonstration of combined use with an advanced optical system. The experimental results demonstrated that our developed AFM is suitable for integration under upright OM and brings AFM high-resolution advantages to the existing OM system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0093080 | DOI Listing |
Pharmaceuticals (Basel)
December 2024
Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307 Dresden, Germany.
(1) : Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of Pb- and Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the Pb/Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) : The routine alpha detection on thin-layer chromatograms (TLC) of Pb- and Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) : For Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken.
View Article and Find Full Text PDFJ Morphol
January 2025
Department of Biology, California State University, Northridge, Northridge, California, USA.
A major goal of evolutionary ecology is to understand the interaction between ecological differences and the functional morphology of organisms. Studies of this type are common among flying birds but less so in penguins. Penguins (Spheniscidae) are the most derived extant underwater flying birds using their wings for swimming and beak when foraging.
View Article and Find Full Text PDFPLoS One
January 2025
Faculty of Science and Technology, University of Canberra, Canberra, ACT, Australia.
We explore the efficacy of multimodal behavioral cues for explainable prediction of personality and interview-specific traits. We utilize elementary head-motion units named kinemes, atomic facial movements termed action units and speech features to estimate these human-centered traits. Empirical results confirm that kinemes and action units enable discovery of multiple trait-specific behaviors while also enabling explainability in support of the predictions.
View Article and Find Full Text PDFJ Craniofac Surg
November 2024
Plastic Reconstructive and Aesthetic Surgery Clinic, Ankara, Turkey.
The aim of this study is to investigate the use of the temporoparietal fascial flap (TPFF) in the repair of tissue defects in the head and neck region. TPFF is a preferred method among surgeons due to its thin and flexible structure and its strong vascular structure supplied by the superficial temporal artery. In the study, the operations performed on a total of 21 patients and the results of these operations were analyzed.
View Article and Find Full Text PDFNeurosurg Rev
January 2025
Department of Neurological Sciences, Christian Medical College Vellore- Ranipet Campus Vellore, Vellore, Tamil Nadu, 632517, India.
To describe the distribution of jugular bulb position and pneumatization of posterior lip of internal auditory meatus (IAM) in patients with vestibular schwannoma (VS). This retrospective study included 43 patients who had a thin slice (< 2 mm) CT temporal bone for preoperative planning of retrosigmoid approach for excision of VS between March 2011 and March 2021. On computed tomography (CT), high riding jugular bulb was defined by its relationship to IAM and correlated with type of jugular bulb according to Manjila et al.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!