[Antibiotic-resistant bacteria contamination in the air of different departments in hospital].

Wei Sheng Yan Jiu

Institute of Environmental Medicine, MOE Key Laboratory of Environment and Health, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.

Published: July 2022

Objective: To investigate the contamination of antibiotic-resistant bacteria in air of different departments in hospital.

Methods: From 2018.07 to 2021.06, 191 samples of the air-conditioning filter dust in three hospitals were collected. Antibiotic-resistant bacteria were isolated from the accumulated dust. The drug sensitivity test was conducted for Staphylococcus aureus, Acinetobacter baumannii and Enterobacteriaceae.

Results: A total of 119 samples were detected antibiotic-resistant bacteria from 191 samples, and the detection rate was 62.30%. The detection rate of different departments from high to low was surgical ward(68.29%) >intensive care unit(ICU)(59.62%) >medical ward(57.92%). A total of 362 strains of antimicribial-resistant organisms were isolated, mainly were Acinetobacter(28.73%), Pseudomonas(22.10%), Bacillus(22.10%), Staphylococcus(9.12%), etc. Among them, 72 strains of target organisms were detected, and the detection rate was 19.89%(72/362), the detection rate of different target bacteria from high to low was Acinetobacter baumannii(12.71%)>Enterobacteriaceae(4.72%)>Staphylococcus aureus(2.76%)(P<0.05). The drug sensitivity test showed that 41 strains of antimicribial-resistant organisms were detected, and the detection rate was 56.94%(41/72), including carbapenem-resistant Acinetobacter baumannii(CR-ABA), methicillin-resistant Staphylococcus aureus(MRSA), carbapenem-resistant Enterobacteriaceae(CRE), etc.24 strains of multidrug-resistant organisms(MDROs) were detected and the detection rate was 58.54%(24/41). The detection rate of different departments from high to low was ICU(80.00%)>medical ward(60.00%)>surgical ward(46.15%).

Conclusion: There was contaminated by Acinetobacter baumannii, Staphylococcus aureus, Enterobacteriaceae in the air of hospitals, some of them were MDROs, mainly were detected in neurological ward, respiratory medical ward, hyroid and breast surgery ward, neurosurgery ward, cardiothoracic surgery ward, gallideulous surgical ICU and general ICU.

Download full-text PDF

Source
http://dx.doi.org/10.19813/j.cnki.weishengyanjiu.2022.04.020DOI Listing

Publication Analysis

Top Keywords

detection rate
28
antibiotic-resistant bacteria
12
high low
12
detected detection
12
air departments
8
191 samples
8
drug sensitivity
8
sensitivity test
8
staphylococcus aureus
8
acinetobacter baumannii
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!