A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single-Unit Short Implants in the Molar Region: A Retrospective Study with a Minimum 3-Year Follow-up. | LitMetric

The high biomechanical loads in molar region wounds challenge the indication for short implants to be used as a single-unit implant. This study reports on the outcomes of single-unit short implants (≤ 8.0 mm) in the maxillary and mandibular molar regions. Forty-nine short implants were placed in 48 patients to replace a missing molar tooth. Two-piece restorations with screw retention were fabricated. During the follow-up, implant survival and marginal bone loss (MBL) were assessed. The known implant length was used as a reference to calibrate the linear measurements on digital periapical radiographs, and descriptive statistical analysis was performed. The implants were followed over a period of 47 ± 12 months. No implant failure was recorded, and no prosthesis failure was observed. The average MBL was 0.15 ± 0.5 mm. The mean crown height space was 13 ± 3 mm. The overall crown-to-implant ratio was 1.7 ± 0.4. Two technical complications occurred due to the loosening of the unit abutment. After screw re-tightening, no more screw loosening was observed. This study supports the use of short implants as a single-unit implant in the maxillary and mandibular molar regions.

Download full-text PDF

Source
http://dx.doi.org/10.11607/prd.5005DOI Listing

Publication Analysis

Top Keywords

short implants
20
single-unit short
8
molar region
8
implants single-unit
8
single-unit implant
8
maxillary mandibular
8
mandibular molar
8
molar regions
8
implants
6
molar
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!