Penalised PET image reconstruction algorithms are often accelerated during early iterations with the use of subsets. However, these methods may exhibit limit cycle behaviour at later iterations due to variations between subsets. Desirable converged images can be achieved for a subclass of these algorithms via the implementation of a relaxed step size sequence, but the heuristic selection of parameters will impact the quality of the image sequence and algorithm convergence rates. In this work, we demonstrate the adaption and application of a class of stochastic variance reduction gradient algorithms for PET image reconstruction using the relative difference penalty and numerically compare convergence performance to BSREM. The two investigated algorithms are: SAGA and SVRG. These algorithms require the retention in memory of recently computed subset gradients, which are utilised in subsequent updates. We present several numerical studies based on Monte Carlo simulated data and a patient data set for fully 3D PET acquisitions. The impact of the number of subsets, different preconditioners and step size methods on the convergence of regions of interest values within the reconstructed images is explored. We observe that when using constant preconditioning, SAGA and SVRG demonstrate reduced variations in voxel values between subsequent updates and are less reliant on step size hyper-parameter selection than BSREM reconstructions. Furthermore, SAGA and SVRG can converge significantly faster to the penalised maximum likelihood solution than BSREM, particularly in low count data.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2022.3203237DOI Listing

Publication Analysis

Top Keywords

pet image
12
image reconstruction
12
step size
12
saga svrg
12
stochastic variance
8
variance reduction
8
relative difference
8
subsequent updates
8
algorithms
6
investigation stochastic
4

Similar Publications

Acute liver injury (ALI) is a prevalent and potentially lethal condition globally, where pharmacotherapy plays a vital role. However, challenges such as rapid drug excretion and insufficient concentration at hepatic lesions often impede the treatment's effectiveness. We successfully prepared glycyrrhizinate monoammonium cysteine (GMC)-loaded lipid nanoparticles (LNPs) using high-pressure homogenization.

View Article and Find Full Text PDF

The radiotracer [F]JK-PSMA-7, a prostate cancer imaging agent for positron emission tomography (PET), was previously synthesized by indirect radiofluorination using an F-labeled active ester as a prosthetic group, which had to be isolated and purified before it could be linked to the pharmacologically active Lys-urea-Glu motif. Although this procedure could be automated on two-reactor modules like the GE TRACERLab FX2N (FXN) to afford the tracer in modest radiochemical yields (RCY) of 18-25%, it is unsuitable for cassette-based systems with a single reactor. To simplify implementation on an automated synthesis module, the radiosynthesis of [F]JK-PSMA-7 was devised as a one-pot, two-step reaction.

View Article and Find Full Text PDF

Aromatase plays a crucial role in the conversion of androgens to oestrogens and is often overexpressed in hormone-dependent tumours, particularly breast cancer. [18F]BIBD-071, which has excellent binding affinity for aromatase and good pharmacokinetics, has potential for the diagnosis and treatment of aromatase-related diseases. The MCF-7 cell line, which is hormone receptor-positive (HR+), was used in the assessment of the novel [18F]-labelled radiotracer [18F]BIBD-071 via positron emission tomography (PET) imaging of an HR+ breast cancer xenograft model.

View Article and Find Full Text PDF

In this study, we assessed the utility of ultrasonography in monitoring the chemotherapeutic effects on primary thyroid lymphoma (PTL). This retrospective analysis included 17 patients with PTL who received chemotherapy from 2012 to 2022. The sonographic features were examined pre- and post-treatment using ultrasound (US) to monitor the treatment response at the first to second, third to fourth, and end cycles of chemotherapy and follow-up, and progression-free survival (PFS) and overall survival (OS) were analyzed.

View Article and Find Full Text PDF

Imaging in Periprosthetic Joint Infection Diagnosis: A Comprehensive Review.

Microorganisms

December 2024

International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA.

Various imaging methods assist in diagnosing periprosthetic joint infection (PJI). These include radiological techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound (US); as well as advanced nuclear medicine techniques including bone scintigraphy (BS), anti-granulocyte antibody imaging (AGS), leukocyte scintigraphy (LS), and fluorodeoxyglucose positron emission tomography (FDG-PET and FDG-PET/CT). Each imaging technique and radiopharmaceutical has been extensively studied, with unique diagnostic accuracy, limitations, and benefits for PJI diagnosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!