Tuning Electrospray Ionization with Low-Frequency Sound.

J Am Soc Mass Spectrom

Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd, Hsinchu 300044, Taiwan.

Published: October 2022

AI Article Synopsis

  • Electrospray ionization mass spectrometry (ESI-MS) is essential for analyzing biomolecules, involving the creation of microdroplets that release ions when desolvated.
  • Low-frequency sound modulation (50-350 Hz) is employed to steer these microdroplets towards the mass spectrometer, allowing for size-based segregation of droplets.
  • This modulation can impact the intensity and selectivity of the mass spectrometry signals, influenced by different ion formation pathways and droplet deflection patterns, supported by additional shadowgraph images.

Article Abstract

Electrospray ionization (ESI) mass spectrometry (MS) is one of the key techniques used in biomolecular analysis nowadays. It relies on formation of polydisperse microdroplets, which undergo desolvation and liberate ions to the gas phase. Here we demonstrate low-frequency-sound-modulated ESI for analysis of biomolecules. By using a low-frequency (50-350 Hz) sound, it is possible to deflect electrospray microdroplets toward the mass spectrometer's orifice. Microdroplets of different sizes are deflected to a different extent leading to a partial size segregation. This effect leads to either an increase or decrease of MS signal intensity as well as signal-to-noise ratio. It also affects the selectivity of the ESI-MS analysis. The observations are rationalized by taking into account different pathways of ion formation and the likelihood of deflecting microdroplets of certain size. The online ESI-MS observations are supported with offline shadowgraphs obtained at varied sound frequencies, signal amplitudes, and phase shifts.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jasms.2c00179DOI Listing

Publication Analysis

Top Keywords

electrospray ionization
8
tuning electrospray
4
ionization low-frequency
4
low-frequency sound
4
sound electrospray
4
ionization esi
4
esi mass
4
mass spectrometry
4
spectrometry key
4
key techniques
4

Similar Publications

A Fast-Pass, Desorption Electrospray Ionization Mass Spectrometry Strategy for Untargeted Metabolic Phenotyping.

J Am Soc Mass Spectrom

January 2025

Department of Chemistry, Center for Innovative Technology, Vanderbilt University, Nashville, Tennessee 37235, United States.

Desorption electrospray ionization mass spectrometry imaging (DESI-MSI) provides direct analytical readouts of small molecules that can be used to characterize the metabolic phenotypes of genetically engineered bacteria. In an effort to accelerate the time frame associated with the screening of mutant libraries, we have developed a high-throughput DESI-MSI analytical workflow implementing a single raster line-scan strategy that facilitates the collection of location-resolved molecular information from engineered strains on a subminute time scale. Evaluation of this "Fast-Pass" DESI-MSI phenotyping workflow on analytical standards demonstrated the capability of acquiring full metabolic profiling information with a throughput of ∼40 s per sample.

View Article and Find Full Text PDF

Identifying the Molecular Signatures of Organic Matter Leached from Land-Applied Biosolids via 21 T FT-ICR Mass Spectrometry.

Environ Sci Technol

January 2025

National High Magnetic Field Laboratory Geochemistry Group and Department of Earth, Ocean, and Atmospheric Science, Florida State University, Tallahassee, Florida 32306, United States.

Intensification of wastewater treatment residual (i.e., biosolid) applications to watersheds can alter the amount and composition of organic matter (OM) mobilized into waterways.

View Article and Find Full Text PDF

A simple and efficient validated assay for quantifying 21-deoxycortisol (21-DOC), 17-hydroxyprogesterone (17-OHP), cortisol, and cortisone in human plasma has been developed using ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). Analysis of plasma samples were performed on Atlantis dC18 (3 m) column using a mobile phase of 20.0 mM ammonium acetate and acetonitrile (50:50, : ) that was delivered at isocratic flow rate 0.

View Article and Find Full Text PDF

The recent unauthorization of antiviral drugs in food-producing animals according to Commission Delegated Regulation (EU) 2022/1644 have increased the need for food control laboratories to develop analytical methods and perform official controls. In this work, a simple and fast analytical methodology was developed for the simultaneous determination of 21 antiviral drugs in chicken muscle and liver by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Chromatographic separation was achieved by an HILIC BEH amide column; followed by detection with a electrospray ionization source in positive and negative modes.

View Article and Find Full Text PDF

A simple, fast, sample-saving, and sensitive liquid chromatography-tandem mass spectrometry method was established with a linear range adjusted by in-source collision-induced dissociation. Notably, this could simultaneously determine busulfan, fludarabine, phenytoin, and posaconazole in plasma from children, each having unique physical and chemical properties. The procedure necessitated only 20 μL of plasma and involved a simple protein precipitation process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!