A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rate and nature of complications with leadless transcatheter pacemakers compared with transvenous pacemakers: results from an Italian multicentre large population analysis. | LitMetric

AI Article Synopsis

  • * A total of 2,669 patients were followed for about 39 months, revealing that L-PM patients had lower device-related complications overall (0.5% vs. 1.9% at 12 months).
  • * While early complication rates were similar for both types, L-PM had significantly fewer late complications, indicating it could be a safer option for patients.

Article Abstract

Aims: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation.

Methods And Results: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 (n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications (P = 0.129), had a similar risk of early complications (≤30 days) (P = 1.000), and had a significantly lower risk of late complications (>30 days) (P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related.

Conclusion: In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10103553PMC
http://dx.doi.org/10.1093/europace/euac112DOI Listing

Publication Analysis

Top Keywords

device-related complications
20
rate nature
12
complications
12
l-pm t-pm
12
l-pm patients
12
risk device-related
12
l-pm
10
nature device-related
8
propensity matching
8
lower l-pm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!