Introduction: Our study aim was to explore how different protamine-heparin ratios impacted enzymatic coagulation and acellular fibrin clot growth in plasma using an in vitro model. We hypothesized that a low protamine-heparin ratio would be associated with superior fibrin clot growth dynamics.
Methods: We performed an in vitro study using 15 plasma samples from a commercial supplier. Different protamine-heparin ratios were added to each donor plasma sample: low ratio (0.7-1), traditional ratio (1-1), and high ratio (1.3-1) and clot formation dynamics were evaluated using a Thrombodynamics analyzer. Study outcomes were initial clot growth velocity and clot size at 30 min.
Results: Plasma samples treated with a one-to-one protamine-heparin ratio had significantly lower mean initial clot growth velocity compared to samples treated with a low protamine-heparin ratio; mean difference -2.3 μm/min (95% CI = -4.0 to -0.7, = .004). Plasma samples treated with a one-to-one protamine-heparin ratio also had significantly smaller mean clot size at 30 min compared to samples treated with a low protamine-heparin ratio; mean difference -54.0 μm (95% CI = -107.6 to -0.4, = .048). There were no significant differences in mean initial clot growth velocity or clot size at 30 min between plasma samples treated with a high protamine-heparin ratio and those treated with a one-to-one or low protamine-heparin ratio (all > .05).
Conclusions: Plasma samples treated with a low protamine-heparin ratio had superior clot growth velocity and larger clot size at 30 min compared to a one-to-one ratio, supporting the notion that a low protamine-heparin ratio may optimize enzymatic coagulation after cardiopulmonary bypass.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/02676591221122365 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!