Background: Preoperative evaluation of macular disorders is crucial to predict postoperative visual outcomes among patients with cataract. The swept-source optical coherence tomography (SS-OCT) based optical biometer was proved to be useful in screening macular pathology, while the impact of lens opacities and axial lengths on macular disease screening using SS-OCT based optical biometer remained unknown. This study aimed to evaluate the influence of lens opacities and axial lengths on foveal image quality detected by SS-OCT-based optical biometer, as well as sensitivity and specificity for the detection of macular diseases.

Methods: This was a diagnostic accuracy study that retrospectively included patients who underwent preoperative cataract examinations at our hospital between November 2020 and June 2021. All patients underwent SS-OCT based optical biometer and spectral-domain OCT (SD-OCT). The SD-OCT was the golden standard for diagnosing macular diseases. Sensitivity, specificity, and receiver operating characteristic (ROC) were calculated to evaluate the value of foveal SS-OCT scans for the detection of macular disease.

Results: Of the 224 eyes enrolled in the study, 82 eyes were diagnosed with macular disease by SD-OCT. The foveal image was almost indistinguishable due to poor quality when the mean grayscale of the image was less than 40. The posterior subcapsular opacity score and the axial length were significantly correlated with the gray density of the foveal image (r=-0.70, P<0.0001 and r=-0.40, P<0.0001). After excluding cases with indistinguishable foveal images (subcapsular opacities score ≥3.5, axial length ≥28.9 mm), the SS-OCT yielded 68% (95% confidence interval, 0.54-0.79) sensitivity and 87% (95% confidence interval, 0.78-0.92) specificity in 136 eyes.

Conclusions: Routine SS-OCT based biometric measurement for the evaluation of macular pathology simultaneously prior to cataract surgery is suggested except for patients with advanced cataract (posterior subcapsular opacities score ≥3.5) and long axial length (≥28.9 mm).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403934PMC
http://dx.doi.org/10.21037/atm-22-341DOI Listing

Publication Analysis

Top Keywords

optical biometer
20
ss-oct based
12
based optical
12
foveal image
12
impact lens
8
axial length
8
swept-source optical
8
optical coherence
8
lens opacities
8
opacities axial
8

Similar Publications

To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.

View Article and Find Full Text PDF

Purpose: To investigate different measures for corneal astigmatism in the context of reconstructed corneal astigmatism (recCP) as required to correct the pseudophakic eye, and to derive prediction models to map measured corneal astigmatism to recCP.

Methods: Retrospective single centre study of 509 eyes of 509 cataract patients with monofocal (MX60P) IOL. Corneal power measured with the IOLMaster 700 keratometry (IOLMK), and Galilei G4 keratometry (GK), total corneal power (TCP2), and Alpin's integrated front (CorT) and total corneal power (CorTTP).

View Article and Find Full Text PDF

Background: To evaluate the ocular biometry agreement and prediction of postoperative refractive outcomes obtained using two swept-source optical coherence tomography (SS-OCT) biometers: Anterion (Heidelberg Engineering, Heidelberg, Germany) and Argos (Alcon, Fort Worth, TX, USA).

Methods: Ambispective analysis was conducted on 105 eyes at the Samsung Medical Center, Seoul, Republic of Korea, between June 2021 and March 2022. Biometric values were assessed using both devices before cataract surgery.

View Article and Find Full Text PDF

Relative anterior microphthalmos (RAM) is a rare ocular condition characterized by disproportionately small anterior segments but normal axial length (corneal diameter < 11 mm and axial length > 20 mm). This study aimed to determine the prevalence of RAM and its association with glaucoma utilizing IOL Master 700 data (Carl Zeiss Meditec, Jena, Germany). A retrospective analysis was conducted of the biometric parameters of 6,407 eyes, and 115 cases of RAM were identified.

View Article and Find Full Text PDF

Purpose: To assess the variability and correlation of ocular biometric parameters in eyes with cataracts and examine their association with age and gender.

Methods: A retrospective analysis was performed on biometric data from 7,458 eyes without retinal pathologies, using an optical biometer equipped with low-coherence reflectometry technology. Pearson's correlation coefficients (r) were used to evaluate the relationships between age, gender, and various ocular parameters, including axial length (AL), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), corneal refractive power (Km), and white-to-white (WTW) measurement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!