Narrow-diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one-year outcomes of extra-narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26-year-old male patient in need of fixed-implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all-ceramic prostheses 12 months after surgery. The 1 year follow-up showed clinical and radiographic success of extra-narrow implant rehabilitation. Also, both regions presented good evolution of peri-implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow-up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra-narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra-narrow implant predictability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9400033PMC
http://dx.doi.org/10.1002/ccr3.6248DOI Listing

Publication Analysis

Top Keywords

maxillary lateral
16
lateral incisors
16
morse taper
12
extra-narrow implant
12
clinical radiographic
8
taper connection
8
implant rehabilitation
8
rehabilitation maxillary
8
limited space
8
12 months surgery
8

Similar Publications

Finite model analysis of different anchorage sites for bone-supported facemask application in unilateral cleft lip and palate.

Am J Orthod Dentofacial Orthop

January 2025

Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. Electronic address:

Introduction: The objective of this study was to evaluate the effects of the miniplate application sites in the maxilla and the applied force vector changes during skeletally supported facemask application in adolescent patients with unilateral cleft lip and palate (UCLP) using finite element model (FEM) analysis.

Methods: A FEM was obtained from a cone-beam computed tomography image of a 12-year-old female patient with UCLP. Miniplates were placed on 3 different sites of the maxilla; 500 g of advancement force was applied bilaterally, parallel (0°), and downward (-30°) to the occlusal plane.

View Article and Find Full Text PDF

Introduction: The objective of this study was to compare the dental and skeletal changes promoted by the miniscrew-anchored cantilever and pendulum appliance for Class II correction.

Methods: This retrospective study involved 52 patients with Class II malocclusion divided into 2 groups according to the treatment received: the miniscrew group (MG) with 23 patients (14 females and 9 males; mean initial age of 12.42 years) treated using the miniscrew-anchored cantilever, and the pendulum group (PG) with 29 patients (21 females and 8 males; mean initial age of 13.

View Article and Find Full Text PDF

Introduction: This study aimed to assess the root resorption and alveolar bone changes of maxillary incisors volumetrically and 3-dimensionally in patients with Class II Division 1 malocclusion who underwent treatments involving the extraction of 4 first premolars with conventional fixed appliances (FAs) vs clear aligners (CAs).

Methods: A total of 320 maxillary incisors from 80 patients were assessed and divided into 2 groups (FAs and CAs), each possessing similar baseline characteristics. Pretreatment and posttreatment cone-beam computed tomography scans were used to analyze linear and volumetric orthodontically induced inflammatory root resorption, alveolar bone thickness (ABT), alveolar bone height (ABH), as well as anteroposterior and vertical movements of maxillary incisors.

View Article and Find Full Text PDF

Tooth shade selection is a fundamental factor in the success of dental restorations, and visual impairment may adversely affect this process. The aim of this cross-sectional clinical study was to determine whether visual impairment influences shade selection using two methods: spectrophotometry and shade guides. : The sample consisted of 2796 maxillary and mandibular teeth, and shade selection was measured subjectively with a shade guide (VITA Classic, VITA Zahnfabrik) and objectively with a spectrophotometer (VITA Easyshade V, VITA Zahnfabrik, Bad Säckingen, Germany).

View Article and Find Full Text PDF

Ectopic Tooth in the Maxillary Sinus With Odontogenic Keratocyst: Treated by Caldwell-luc Surgery and Bone Lid Technique.

J Craniofac Surg

January 2025

Department of Oral, Plastic, and Aesthetic Surgery, Hospital of Stomatology, Jilin University, Changchun, Jilin, China.

Odontogenic keratocysts (OKCs) are an invasive type of odontogenic cyst that rarely occurs in the maxilla. This article presents a case of OKC complicated with ectopic teeth occurring in the maxillary sinus. This article collects a case of a 19-year-old female patient with an ectopic tooth in the maxillary sinus associated with an OKC.

View Article and Find Full Text PDF