To study spectrum of high resolution computed tomography (HRCT) imaging findings in otosclerosis, to predict approximate length of prosthesis required from pre-operative HRCT measurements and to correlate between oval window niche (OWN) height preoperatively and difficulty in introducing foot plate perforator during surgery. A cross sectional study was conducted on 23 patients with a clinical diagnosis of otosclerosis from September 2018 to July 2020. Sensitivity of HRCT in detecting otosclerosis, correlation between pre-operative incudo-stapedial length (ISL) and intra operative prosthesis length, and correlation between OWN height and difficulty in introducing perforator were sought. The mean age of 23 patients studied was 39.9 years with a female preponderance of 56.5%. 17 out of 19 patients with foci of otosclerosis during surgery had HRCT findings of otosclerosis providing a sensitivity of 89.5%. Mean OWN height obtained was 1.29 mm preoperatively and a cut off value of 1.325 mm found using receiver operating characteristic curve method classifying OWN height as narrow or normal. Mean ISL measured pre operatively was 4.25 mm and mean length of prosthesis used was 4.56 mm with significant positive correlation using intraclass correlation coefficient method with correlation coefficient = 0.879. HRCT is an invaluable modality aiding the surgeon to detect otosclerotic foci with high sensitivity, identify thick obliterative otosclerotic foci requiring additional drilling, to predict the length of prosthesis used and to predict difficulties in approaching footplate when OWN height is below 1.325 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9411290PMC
http://dx.doi.org/10.1007/s12070-021-02428-9DOI Listing

Publication Analysis

Top Keywords

length prosthesis
12
otosclerosis surgery
8
findings otosclerosis
8
difficulty introducing
8
otosclerotic foci
8
otosclerosis
6
hrct
5
length
5
height
5
correlation
5

Similar Publications

This novel hybrid single-double-single barrel (1-2-1) design for fibula free flap reconstruction addresses the unique challenges presented by Brown Class III mandibular defects, which involve long-span defects at both bodies of the mandible and the chin. The importance of this design lies in its ability to overcome the limitations of traditional approaches in terms of mandible height and pedicle length, while optimizing both functional and esthetic outcomes.The technique utilizes a combination of single-double-single barrel fibula segments to achieve ideal esthetics and support for dental prosthesis across different areas of the mandible.

View Article and Find Full Text PDF

Insertion of inflatable penile prosthesis (IPP) is generally regarded as a safe procedure, with low rates of complications. However, when complications do arise, they can pose significant challenges to both patients and surgeons. Patient optimization and adherence to specific intraoperative protocols are crucial in mitigating the risk of surgical complications.

View Article and Find Full Text PDF

Objective: By comparing the hip arthroplasty parameters planned with the AIHIP three-dimensional simulation surgery system, this study analyzes the accuracy of the new femoral-side "shoulder-to-shoulder" artificial anatomical marker positioning method in femoral-side prosthesis implantation and the prevention of leg length discrepancy in hip arthroplasty.

Methods: A retrospective collection of 47 patients who underwent initial total hip arthroplasty at our hospital from August 2020 to December 2022 and met the inclusion and exclusion criteria was used as the study subjects. The average age was 67.

View Article and Find Full Text PDF
Article Synopsis
  • Patients with transfemoral amputation often face issues related to socket fit and overuse injuries due to uneven joint stress, which can be improved by using bone-anchored prosthetics that connect directly to the bone.
  • This study investigates the relationship between the alignment of the femur and pelvis and how it impacts hip loading asymmetry during walking, both before and one year after receiving a bone-anchored limb implant.
  • The analysis included 19 participants from a larger group who underwent the surgery, comparing their skeletal alignment and hip motion data collected at two different time points to determine the effects of the implantation on their mobility and joint loading.
View Article and Find Full Text PDF

Total hip arthroplasty preoperative planning for childhood hip disorders' sequelae: Focus on developmental dysplasia of the hip.

World J Orthop

December 2024

Department of Trauma and Orthopaedics, AOSP Terni, Terni 05100, Italy.

Developmental dysplasia of the hip (DDH) poses significant challenges in both childhood and adulthood, affecting up to 10 per 1000 live births in the United Kingdom and United States. While newborn screening aims to detect DDH early, missed diagnoses can lead to severe complications such as hip dysplasia and early onset osteoarthritis in adults. Treatment options range from less invasive procedures like hip-preserving surgery to more extensive interventions such as total hip arthroplasty (THA), depending on the severity of the condition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?