Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Detection of latent Mycobacterium tuberculosis (LTBI) in patients is important to prevent active infection and the spread of disease, particularly in vulnerable patient populations. In 2020, a kit on the high throughput Liaison XL (DiaSorin) became commercially available for the analysis of QuantiFERON-TB Gold Plus assay (Qiagen). Pilot testing indicated suboptimal repeatability of some samples with this assay. This study provides an extensive assessment of repeatability with DiaSorin system.
Results: Repeat testing of 481 IGRA positive samples, demonstrated substantial variability upon repeat analysis. Repeat results for TB1 and TB2 tubes, showed 73.73% and 72.82% concordance with initial results, respectively. TB1 and TB2 tube values minus the nil (IU/mL) were significantly higher in samples that were repeat positive (p < 0.001). Repeat results had better concordance with initial results if both TB1 and TB2 tubes were positive. Samples with TB1 tube values minus the nil (IU/mL) ≥ 4.54 and TB2 tube values minus the nil (IU/mL) ≥ 4.78 were found to always repeat positive. Assigning a threshold of 1.55 IU/mL for the TB1 tube value minus the nil and 1.45 IU/mL for the TB2 tube value minus the nil yielded a positive predictive value ≥95%.
Conclusion: These results identified a potential role for retesting of select IGRA positive samples on the Diasorin Liaison XL platform due to the high proportion of samples that show a lack of repeatability. Additionally, we identified a threshold that would determine samples most likely to repeat test positive and which samples should be retested.