Control applications targeting fast industrial processes rely on real-time feasible implementations. One of such applications is the stabilization of an electron bunch arrival time in the context of a linear accelerator. In the past, only the electric field accelerating the electron bunches was actively controlled in order to implicitly stabilize the accelerated electron beam. Nowadays, beam properties are specifically measured at a target position and then stabilized by a dedicated feedback loop acting on the accelerating structures. This dedicated loop is usually referred to as a beam-based feedback (BBF). Following this, the control system of the electron linear accelerator for beams with high brilliance and low emittance (ELBE) is planned to be upgraded by the BBF, and the problem of implementing a designed control algorithm becomes highly relevant. In this work, we propose a real-time feasible implementation of a high-order H2 regulator based on a field-programmable gate array (FPGA). By presenting simulation and synthesis results made in hardware description language (HDL) VHDL, we show that the proposed digital solution is fast enough to cover the bunch repetition rates frequently used at ELBE, such as 100 kHz. Finally, we verify the implementation by using a dedicated FPGA testbench.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9412282 | PMC |
http://dx.doi.org/10.3390/s22166236 | DOI Listing |
J Appl Clin Med Phys
January 2025
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, Netherlands.
Introduction: This paper describes a method to improve gantry-dependent beam steering for Elekta traveling wave linear accelerators by applying the measured and filtered beam servo corrections to the existing lookup table (LUT). Beam steering has a direct influence on the treatment accuracy by affecting the beam symmetry and position. The presented method provides an improved LUT with respect to the default Elekta method to reduce treatment delivery interruptions.
View Article and Find Full Text PDFJ Appl Clin Med Phys
January 2025
University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany.
Purpose: The self-shielding radiosurgery system ZAP-X consists of a 3 MV linear accelerator and eight round collimators. For this system, it is a common practice to perform the reference dosimetry using the largest 25 mm diameter collimator at a source-to-axis distance (SAD) of 45 cm with the PTW Semiflex3D chamber placed at a measurement depth of 7 mm in water. Existing dosimetry protocols do not provide correction for these measurement conditions.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Department of Chemical Engineering, Stanford University, Stanford, CA 94305.
High degree of fluorination for ether electrolytes has resulted in improved cycling stability of lithium metal batteries due to stable solid electrolyte interphase (SEI) formation and good oxidative stability. However, the sluggish ion transport and environmental concerns of high fluorination degree drive the need to develop less fluorinated structures. Here, we depart from the traditional ether backbone and introduce bis(2-fluoroethoxy)methane (F2DEM), featuring monofluorination of the acetal backbone.
View Article and Find Full Text PDFCancers (Basel)
December 2024
Radiation Oncology Department, Centre Frederic Joliot, 76000 Rouen, France.
Background/objectives: An on-board imager on a linear accelerator allows the acquisition of kV-2D images during irradiation. Overlaying specific structures on these images enables the visual verification of movement at regular frequencies. Our aim was to validate this tracking method for the stereotactic treatment of bone metastases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!