Personalization of Hearing Aid Fitting Based on Adaptive Dynamic Range Optimization.

Sensors (Basel)

Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX 75080-3021, USA.

Published: August 2022

Adaptive dynamic range optimization (ADRO) is a hearing aid fitting rationale which involves adjusting the gains in a number of frequency bands by using a series of rules. The rules reflect the comparison of the estimated percentile occurrences of the sound levels with the audibility and comfort hearing levels of a person suffering from hearing loss. In the study reported in this paper, a previously developed machine learning method was utilized to personalize the ADRO fitting in order to provide an improved hearing experience as compared to the standard ADRO hearing aid fitting. The personalization was carried out based on the user preference model within the framework of maximum likelihood inverse reinforcement learning. The testing of ten subjects with hearing loss was conducted, which indicated that the personalized ADRO was preferred over the standard ADRO on average by about 10 times. Furthermore, a word recognition experiment was conducted, which showed that the personalized ADRO had no adverse impact on speech understanding as compared to the standard ADRO.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9414822PMC
http://dx.doi.org/10.3390/s22166033DOI Listing

Publication Analysis

Top Keywords

hearing aid
12
aid fitting
12
standard adro
12
adaptive dynamic
8
dynamic range
8
range optimization
8
adro hearing
8
hearing loss
8
compared standard
8
personalized adro
8

Similar Publications

Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs).

Study Design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP.

Setting: Tertiary referral center.

View Article and Find Full Text PDF

Detection of Extracochlear Electrodes Using Electrical Field Imaging (EFI).

Otol Neurotol

February 2025

Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.

Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).

Study Design: Retrospective cohort study.

Setting: Tertiary academic medical center.

View Article and Find Full Text PDF

Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.

Study Design: Prospective performance study.

Setting: Secondary care.

View Article and Find Full Text PDF

Objective: This study aims to evaluate the potential association of perioperative hearing outcomes with frailty by Modified 5-Item Frailty Index (mFI-5).

Design: Retrospective cross-sectional study.

Setting: Single-institutional study conducted at a tertiary care hospital between January 2018 and January 2022.

View Article and Find Full Text PDF

Objective: To investigate the association between postoperative antibiotic prophylaxis and the risk of infections leading to implant explantation or hospitalization, with a follow-up of up to 12 years.

Study Design: Retrospective cohort study.

Setting: Tertiary medical institution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!