Erosion of the elbow due to non-Newtonian viscous slurry flows is often observed in hydrocarbon transportation pipelines. This paper intends to study the erosion behavior of double offset U-bends and 180° U-bends for two-phase (liquid-sand) flow. A numerical simulation was conducted using the Discrete Phase Model (DPM) on carbon steel pipe bends with a 40 mm diameter and an R/D ratio of 1.5. The validity of the erosion model has been established by comparing it with the results quantified in the literature by experiment. While the maximum erosive wear rates of all evaluated cases were found to be quite different, the maximum erosion locations have been identified between 150° and 180° downstream at the outer curvature. It was seen that with the increase in disperse phase diameter, the erosive wear rate and impact area increased. Moreover, with the change of configuration from a 180° U-bend to a double offset U-bend, the influence of turbulence on the transit of the disperse phase decreases as the flow approaches downstream and results in less erosive wear in a double offset U-bend. Furthermore, the simulation results manifest that the erosive wear increases with an increase in flow velocity, and the erosion rate of the double offset U-bend was nearly 8.58 times less than the 180° U-bend for a carrier fluid velocity of 2 m/s and 1.82 times less for 4 m/s carrier fluid velocity. The erosion rate of the double offset U-bend was reduced by 120% compared to the 180° U-bend for 6 m/s in liquid-solid flow.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9414689PMC
http://dx.doi.org/10.3390/ma15165558DOI Listing

Publication Analysis

Top Keywords

erosive wear
20
double offset
20
offset u-bend
16
180° u-bend
12
u-bend
8
disperse phase
8
velocity erosion
8
erosion rate
8
rate double
8
carrier fluid
8

Similar Publications

We investigated the phase transitions, mechanical properties, and chemical durability of a composition of 9 mol% CaO-stabilized zirconia (9CSZ) doped with 2-4 mol% CeO under thermal stress against molten slag. The monoclinic phase fraction of 9CSZ was 7.14% at room temperature, and CSZ doped with 2-4 mol% CeO showed a slightly lower value of 5.

View Article and Find Full Text PDF

Background: Heterogeneous results are to be expected when multiple raters diagnose whether the dentine of a tooth with erosive tooth wear (ETW) is exposed or not. Identification of notions (fundamental concepts and understanding) about the diagnostic problem shared by groups of raters can be helpful to develop guidelines and to optimize teaching and calibration procedures. We aim to illustrate how clusters of raters with a common notion can be identified and how first insights about the notions can be obtained.

View Article and Find Full Text PDF

Collagen/polyvinyl alcohol scaffolds combined with platelet-rich plasma to enhance anterior cruciate ligament repair.

Biomater Adv

December 2024

College of Biological Science and Engineering, Fuzhou University, No. 2 Xueyuan Road, Fuzhou 350108, China; Fujian Key Laboratory of Medical Instrument and Pharmaceutical Technology, Fuzhou University, No. 2 Xueyuan Road, Fuzhou 350108, China. Electronic address:

In anterior cruciate ligament (ACL) repair methods, the continuous enzymatic erosion of synovial fluid can impede healing and potentially lead to repair failure, as well as exacerbate articular cartilage wear, resulting in joint degeneration. Inspired by the blood clot during medial collateral ligament healing, we developed a composite scaffold comprising collagen (1 %, w/v) and polyvinyl alcohol (5 %, w/v) combined with platelet-rich plasma (PRP). The composite scaffold provides a protective barrier against synovial erosion for the ruptured ACL, while simultaneously facilitating tissue repair, thereby enhancing the efficacy of ACL repair techniques.

View Article and Find Full Text PDF

Aims: Hemiarthroplasty (HA) and total shoulder arthroplasty (TSA) are often the preferred forms of treatment for patients with atraumatic avascular necrosis of the humeral head when conservative treatment fails. Little has been reported about the survival of HA and TSA for this indication. The aim of this study was to investigate the differences in revision rates between HA and TSA in these patients, to determine whether one of these implants has a superior survival and may be a better choice in the treatment of this condition.

View Article and Find Full Text PDF

Erosive tooth wear (ETW) is a prevalent oral condition with varying etiology, including erosion, abrasion, abfraction, and attrition. It is reported in the literature in different nomenclatures, hindering the ability to identify the emerging trends and influential scholarly works and bodies within this field. Using a bibliometric analysis approach, this study aims to evaluate the trends, themes, and productivity of the research on ETW condition while respecting its different terminologies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!