A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a Portico™ transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNav™ DS. The objective of this registry is to characterize the procedural safety and device performance of the Portico™ THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria. The implantation of a single Portico™ THV was successful in 97.5% of subjects. The 30-day all-cause mortality, cardiovascular mortality, and disabling stroke rates were 2.6%, 2.1%, and 1.8%, respectively. A new pacemaker was implanted in 19.0% of subjects at 30 days. At 30 days, the effective orifice area and mean gradient values were 1.82 cm and 7.1 mmHg, respectively. The 30-day rate of moderate paravalvular leak (PVL) was 2.1%, with no occurrence of severe PVL. The Portico™ THV demonstrated improved hemodynamic performance and low rates of safety events at 30 days in a large cohort of subjects implanted with the Portico™ THV with either the first-generation DS or FlexNav™ DS.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9409954 | PMC |
http://dx.doi.org/10.3390/jcm11164839 | DOI Listing |
Catheter Cardiovasc Interv
December 2024
Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.
Background: Hypoattenuating leaflet thickening (HALT) following transcatheter aortic valve replacement (TAVR) may compromise valve durability, posing a significant barrier to the broader adoption of this technology among younger patients. Self-expanding valves (SEVs) are the most commonly used transcatheter heart valves (THVs) among Chinese patients with aortic stenosis. Understanding the potential mechanisms underlying HALT is, therefore, critical to guide future THV design and development.
View Article and Find Full Text PDFEng Comput
June 2024
Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN USA.
Heart valves play a critical role in maintaining proper cardiovascular function in the human heart; however, valve diseases can lead to improper valvular function and reduced cardiovascular performance. Depending on the extent and severity of the valvular disease, replacement operations are often required to ensure that the heart continues to operate properly in the cardiac system. Transcatheter aortic valve replacement (TAVR) procedures have recently emerged as a promising alternative to surgical replacement approaches because the percutaneous methods used in these implant operations are significantly less invasive than open heart surgery.
View Article and Find Full Text PDFEuroIntervention
December 2024
Royal North Shore Hospital, Sydney, Australia.
Transcatheter aortic valve implantation (TAVI) is a safe and effective procedure for the treatment of aortic stenosis. With the recently broadened indications, there is a larger cohort of patients likely to outlive their first transcatheter heart valve (THV). This review discusses relevant lifetime planning considerations, focusing on the utility of preprocedural computed tomography imaging to help implanters future-proof their patients who are likely to outlive their first valve.
View Article and Find Full Text PDFEuroIntervention
December 2024
Harrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
Background: No data compare newer-generation transcatheter heart valves (THVs) in terms of next-day discharge (NDD) following transfemoral (TF) transcatheter aortic valve implantation (TAVI).
Aims: We aimed to evaluate the safety of NDD in unselected patients who received ACURATE (neo/neo2), Evolut (PRO/PRO+/FX) and the SAPIEN (3/Ultra) THVs.
Methods: This multicentre registry included patients who underwent TF-TAVI without a preprocedural permanent pacemaker implantation (PPI) and were discharged the next day without a new PPI.
Heart Lung Circ
December 2024
Department of Cardiovascular Diseases, Mayo Clinic College of Medicine, Rochester, MN, USA. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!