Objective: Previous studies have reported conflicting findings regarding aldosterone levels in patients hospitalised with COVID-19. We therefore used the gold-standard technique of liquid chromatography-tandem mass spectrometry (LCMSMS) to address this uncertainty.

Design: All patients admitted to Cambridge University Hospitals with COVID-19 between 10 March 2020 and 13 May 2021, and in whom a stored blood sample was available for analysis, were eligible for inclusion.

Methods: Aldosterone was measured by LCMSMS and by immunoassay; cortisol and renin were determined by immunoassay.

Results: Using LCMSMS, aldosterone was below the limit of detection (<70 pmol/L) in 74 (58.7%) patients. Importantly, this finding was discordant with results obtained using a commonly employed clinical immunoassay (Diasorin LIAISON®), which over-estimated aldosterone compared to the LCMSMS assay (intercept 14.1 (95% CI -34.4 to 54.1) + slope 3.16 (95% CI 2.09-4.15) pmol/L). The magnitude of this discrepancy did not clearly correlate with markers of kidney or liver function. Solvent extraction prior to immunoassay improved the agreement between methods (intercept -14.9 (95% CI -31.9 to -4.3) and slope 1.0 (95% CI 0.89-1.02) pmol/L) suggesting the presence of a water-soluble metabolite causing interference in the direct immunoassay. We also replicated a previous finding that blood cortisol concentrations were often increased, with increased mortality in the group with serum cortisol levels > 744 nmol/L (P = 0.005).

Conclusion: When measured by LCMSMS, aldosterone was found to be profoundly low in a significant proportion of patients with COVID-19 at the time of hospital admission. This has likely not been detected previously due to high levels of interference with immunoassays in patients with COVID-19, and this merits further prospective investigation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9578067PMC
http://dx.doi.org/10.1530/EC-22-0190DOI Listing

Publication Analysis

Top Keywords

hospitalised covid-19
8
measured lcmsms
8
lcmsms aldosterone
8
patients covid-19
8
aldosterone
5
covid-19
5
patients
5
unquantifiably low
4
low aldosterone
4
aldosterone concentrations
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!