Background: Although hypertension is a risk factor for severe Coronavirus Disease 2019 (COVID-19) illness, little is known about the effects of COVID-19 on blood pressure (BP). Central BP measures taken over a 24-hour period using ambulatory blood pressure monitoring (ABPM) adds prognostic value in assessing cardiovascular disease (CVD) risk compared with brachial BP measures from a single time point. We assessed CVD risk between adults with and without a history of COVID-19 via appraisal of 24-hour brachial and central hemodynamic load from ABPM.
Methods: Cross-sectional analysis was performed on 32 adults who tested positive for COVID-19 (29 ± 13 years, 22 females) and 43 controls (28 ± 12 years, 26 females). Measures of 24-hour hemodynamic load included brachial and central systolic and diastolic BP, pulse pressure, augmentation index (AIx), pulse wave velocity (PWV), nocturnal BP dipping, the ambulatory arterial stiffness index (AASI), and the blood pressure variability ratio (BPVR).
Results: Participants who tested positive for COVID-19 experienced 6 ± 4 COVID-19 symptoms, were studied 122 ± 123 days after testing positive, and had mild-to-moderate COVID-19 illness. The results from independent samples t-tests showed no significant differences in 24-hour, daytime, or nighttime measures of central or peripheral hemodynamic load across those with and without a history of COVID-19 (P > 0.05 for all).
Conclusions: No differences in 24-hour brachial or central ABPM measures were detected between adults recovering from mild-to-moderate COVID-19 and controls without a history of COVID-19. Adults recovering from mild-to-moderate COVID-19 do not have increased 24-hour central hemodynamic load.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9452129 | PMC |
http://dx.doi.org/10.1093/ajh/hpac100 | DOI Listing |
Medicine (Baltimore)
January 2025
Student Research Committee, School of Nutrition and Food Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
A recently introduced metric for assessing metabolic syndrome (MetS) is the triglyceride glucose-body mass index (TyG-BMI). Additionally, the glycemic index (GI) is recognized as a significant measure for evaluating conditions associated with blood glucose. In this context, our research explores the correlation between TyG-BMI and GI in relation to diet quality, anthropometric measurements, and blood pressure among individuals diagnosed with MetS.
View Article and Find Full Text PDFLife Sci
January 2025
Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 69, 8200 Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University Hospital, Palle Juul-Jensens Boulevard 11, 8200 Aaarhus N, Denmark.
Background: Butyrate, a short-chain fatty acid, has shown potential to improve left ventricular (LV) function and induce vasorelaxation in rodents. Butyrate may either be produced by the microbiome in the colon, be ingested or administered intravenously. This study aimed to evaluate effects of butyrate on cardiac output (CO) and associated hemodynamic variables in a porcine model.
View Article and Find Full Text PDFPhysiol Rep
January 2025
Faculty of Health Science and Medicine, Bond University, Robina, Queensland, Australia.
Police officers are exposed to high levels of stress. Serving on Special Weapons and Tactics (SWAT) teams is a highly demanding duty that may further increase levels of stress in police personnel. This stress may accumulate, thereby increasing allostatic load.
View Article and Find Full Text PDFSci Rep
January 2025
China Institute of Sport and Health Science, Beijing Sport University, Beijing, 100084, China.
This study explored the effects of training weight and amplitude in whole-body vibration (WBV) on exercise intensity, indicated by oxygen consumption (VO) and heart rate. In LOAD-study: ten participants performed squats under non-WBV and WBV (30 Hz 2 mm) conditions at 0%, 40%, and 80% bodyweight (BW). In AMPLITUDE-study: eight participants performed squats under non-WBV, low-amplitude WBV (30 Hz 2 mm), and high-amplitude WBV (30 Hz 4 mm) conditions with 0% and 40%BW.
View Article and Find Full Text PDFArterial compliance (AC) is an important cardiovascular parameter characterizing mechanical properties of arteries. AC is significantly influenced by arterial wall structure and vasomotion, and it markedly influences cardiac load. A new method, based on a two-element Windkessel model, has been recently proposed for estimating AC as the ratio of the time constant T of the diastolic blood pressure decay and peripheral vascular resistance derived from clinically available stroke volume measurements and selected peripheral blood pressure parameters which are less prone to peripheral distortions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!