A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sustainable and green persulfate-based chemiluminescent method for on-site estimation of chemical oxygen demand in waters. | LitMetric

Sustainable and green persulfate-based chemiluminescent method for on-site estimation of chemical oxygen demand in waters.

Anal Chim Acta

MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, c/ Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.

Published: August 2022

The standard method for estimating the chemical oxygen demand (COD) of water bodies uses dichromate as the main oxidant, a chemical agent whose use has been restricted in the European Union since 2017. This method is hazardous, time-consuming, and burdensome to adapt to on-site measurements. As an alternative and following the current trends of sustainable and green chemistry, a method using the less toxic reagent sodium persulfate as the oxidizing agent has been developed. In this method an excess of persulfate, activated through heating in an alkaline solution, oxidizes the chemically degradable organic fraction through a 2-step radical mechanism. The remaining persulfate is evaluated by chemiluminescence (CL) using luminol and a portable charge-coupled device (CCD) camera. The method provided quantitative recoveries and a sample throughput of >60 samples h. It was validated in river water samples by comparison of COD estimations with the standard dichromate method (R = 0.973, p < 0.05) and with a UV-Vis permanganate-based method (R = 0.9998, p < 0.05), the latter being also used for drinking waters. The proposed method is a sustainable and green alternative to the previous used methods. Overall, the method using activated persulfate is suitable for use as COD quantitation/screening tool in surface waters. Considering that its main components are portable, it can be ultimately adapted for in situ analysis at the point of need.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2022.340196DOI Listing

Publication Analysis

Top Keywords

sustainable green
8
chemical oxygen
8
oxygen demand
8
method
7
green persulfate-based
4
persulfate-based chemiluminescent
4
chemiluminescent method
4
method on-site
4
on-site estimation
4
estimation chemical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!