Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Globally, the sanitation needs of three billion people are met by non-sewered sanitation. Small-footprint treatment technologies are needed that are appropriate for dense urban areas. Blackwater (BW) (or fecal sludge), contains more than 95% liquid, and dewatering it without conditioning requires large footprints. Chemically-enhanced dewatering with conditioners is a promising option to increase dewatering performance and reduce required footprints. However, before implementation of this solution there is a need for increased knowledge on selection and dosing of conditioners. This study evaluated bio-based and synthetic conditioners (chitosan, tannin-, and starch-based, synthetic with and without poly-acrylamide) with 14 types of BW from five countries. The supernatant after settling with jar-tests was analyzed to quantify optimal dose and dewatering performance. The reduction of total chemical oxygen demand (COD) was >55%, achieved by removal of particulate constituents with mainly soluble COD remaining in the supernatant. A reduction in particulate COD could lead to increased efficiency of soluble COD in supernatant treatment. Bio-based conditioners are as effective as synthetic conditioners, and when performance was variable, it was due to differing properties of TSS, TS, EC and pH. Optimal conditioner dose for synthetic conditioners and chitosan could be predicted using concentrations of total solids (TS) (R > 0.7), whereas optimal dose for starch- and tannin-based conditioners could be predicted with electrical conductivity (EC) (R > 0.8), and colloid titration (R > 0.8). In addition, real-time optical TSS and EC sensors could accurately predict chitosan dose for fresh BW treated at source (R = 0.97, R = 0.95). This study validates that use of conditioners for dewatering with highly variable BW can be implemented with real-time measurements for optimal dose, in globally relevant implementations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jenvman.2022.115961 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!