Objective: The objective of the study was to determine the diagnostic performance of the GenoQuick MTB test on heated sputum against the conventional Lowenstein-Jensen culture as the reference method for tuberculosis diagnosis.

Introduction: Fast, reliable, and easy-to-use tests for tuberculosis diagnosis are essential to achieving the Sustainable Development Goal of diagnosing and treating 90% of tuberculosis patients by 2030. We evaluated the diagnostic performance of the GenoQuick MTB, a polymerase chain reaction-lateral flow test, in Uganda, a resource-constrained, high tuberculosis- and HIV-burden setting.

Methods: Fresh sputum samples from presumptive tuberculosis patients at Mulago Hospital were tested for using smear microscopy, GenoQuick MTB test, and Lowenstein-Jensen culture. For the GenoQuick MTB test, mycobacterial DNA was extracted by heating sputum at 95°C for 30 min while DNA amplification and detection were done following the manufacturer's protocol (Hain Lifescience, Nehren, Germany). Sensitivity, specificity, and agreements were calculated against Lowenstein-Jensen culture as a reference test using STATA V12.

Results: Of the 86 tested samples, 30.2% had culture-confirmed pulmonary tuberculosis. Overall, sensitivity was higher for GenoQuick MTB (81%, 95% confidence interval: 60%-93%) than for smear microscopy (69%, 95% confidence interval: 48%-86%). Among people living with HIV, sensitivity was identical for GenoQuick MTB and smear tests (75%, 95% confidence interval: 42%-95%). Contrastingly, smear had a higher overall specificity (98%, 95% confidence interval: 91%-100%) than for GenoQuick MTB (92%, 95% confidence interval: 81%-97%). A similar trend of specificity was observed among the people living with HIV for smear microscopy (100%, 95% CI: 87%-100%) and for GenoQuick MTB (96%, 95% confidence interval: 81%-100%).

Conclusion: The GenoQuick MTB test could be a potential tuberculosis diagnostic test given its higher sensitivity. Evaluation of this test in larger studies is recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9386833PMC
http://dx.doi.org/10.1177/20503121221116861DOI Listing

Publication Analysis

Top Keywords

genoquick mtb
40
95% confidence
24
confidence interval
24
mtb test
20
lowenstein-jensen culture
12
smear microscopy
12
mtb
10
test
9
genoquick
9
diagnostic performance
8

Similar Publications

Objective: The objective of the study was to determine the diagnostic performance of the GenoQuick MTB test on heated sputum against the conventional Lowenstein-Jensen culture as the reference method for tuberculosis diagnosis.

Introduction: Fast, reliable, and easy-to-use tests for tuberculosis diagnosis are essential to achieving the Sustainable Development Goal of diagnosing and treating 90% of tuberculosis patients by 2030. We evaluated the diagnostic performance of the GenoQuick MTB, a polymerase chain reaction-lateral flow test, in Uganda, a resource-constrained, high tuberculosis- and HIV-burden setting.

View Article and Find Full Text PDF

Several molecular systems for direct detection of Mycobacterium tuberculosis complex (MTBC) have recently been developed. The GenoQuick MTB assay (GQ-MTB) used in this study detected 82 of the 96 (85.4%) samples with MTBC, including 50 of 64 (78.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!