Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Anterior segment evaluation using Scheimpflug imaging with the Pentacam scanner allows the acquisition of a plethora of information. It aids in screening and diagnosing corneal pathologies and determining suitability for keratorefractive procedures. This research has significant benefits in terms of establishing normative tomographic values, which is crucial in countries where Keratoconus (KC) is more prevalent, especially among young age group, along with aiding future research in the field of refractive surgery by providing relevant normative data.
Methods: A retrospective review of digital corneal tomography images for a group of medically and ophthalmologically free males aged between 18 and 21 years with 20/20 unaided distant visual acuity was performed.
Results: A total of 1272 subjects (2544 eyes) were included. Findings revealed a mean maximal corneal curvature (Kmax) of 42.91 ± 1.40D (range 36.90-47.80D). The mean flat keratometry (K1) was 41.87 ± 1.31D (range 36.00-46.40D). The mean steep keratometry (K2) was 42.66 ± 1.35D (range 36.70-47.60D). The mean corneal astigmatism (CA) was 0.79 ± 0.37D (range 0.00D-2.30D). The mean central corneal thickness (CCT) was 558.53 ± 33.84 μm (range 421-677 μm). The mean thinnest corneal location thickness (TCLT) was 551.64 ± 34.08 μm (range 417-669μm). The mean corneal diameter (CD) and anterior chamber depth (ACD) were 12.13 ± 0.39 mm (range 10.50-13.60 mm) and 3.12 ± 0.29 mm (range 2.08-4.08 mm), respectively. The median differences between both eyes of the same subject were as follows: kmax difference of 0.20D (IQR 0.1-0.4); K1, K2 and CA difference of 0.20D (IQR 0.1-0.3) for all 3 parameters; CCT and TCLT difference of 5.00 μm (IQR 3.0-9.0) and 6.00 μm (IQR 3.0-10.0), respectively; CD difference of 0.10 mm (IQR 0.0-0.1); and ACD difference of 0.04 (IQR 0.02-0.06).
Conclusion: We believe our data can aid in establishing normative tomographic values and acceptable differences between both eyes. Our data may also help detect subtle corneal pathology and be useful for researchers and innovators in the field of ophthalmology.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9385131 | PMC |
http://dx.doi.org/10.2147/OPTH.S376411 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!