A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Complications associated with PEAK PlasmaBlade from 2010 to 2020 from MAUDE. | LitMetric

The pulse-electron avalanche knife (PEAK) PlasmaBlade 3.0 and 4.0 (Medtronic, Minneapolis, MN) is an electrosurgical technology that is widely used in surgery. Our study aimed to summarize device malfunctions, patient injuries, and interventions related to PEAK PlasmaBlade 3.0 and 4.0. The US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database was queried for reports of PlasmaBlade adverse events from June 6, 2010, to August 30, 2020. Data were extracted from reports pertaining to PlasmaBlade 3.0 and 4.0. A total of 384 medical device reports were identified, from which 424 adverse events were extracted. Of those, 348 (82.1%) were device malfunctions, 53 (12.5%) were patient injuries, and 23 (5.4%) were operator injuries. Device malfunctions were most frequently caused by delaminated coating (110, 25.9%), followed by ignition or fire (56, 13.2%). Operator injury was most frequently caused by thermal injury (19, 4.5%), followed by laceration (4, 0.9%). Pacemakers (22, 57.9%) were the most common devices causing interference. PEAK PlasmaBlade 3.0 and 4.0 have demonstrated utility during surgeries but are associated with adverse events. Interventions that aim to educate physicians on potential risks may help reduce the incidence of complications. Future studies with standardized reporting protocols are warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373757PMC
http://dx.doi.org/10.1080/08998280.2022.2075686DOI Listing

Publication Analysis

Top Keywords

peak plasmablade
16
device malfunctions
12
adverse events
12
patient injuries
8
frequently caused
8
plasmablade
6
device
5
complications associated
4
peak
4
associated peak
4

Similar Publications