Background: High power-ablation index (HP-AI)-guided ablation for atrial fibrillation (AF) targeting high AIs has been implemented in European countries. However, milder AI targets are widely used in Asia. The safety and efficacy of HP-AI-guided ablation compared with those of low-power AI-guided ablation in a milder AI-targeting setting are unknown. The goal of this study was to explore the efficacy and safety of HP-AI-guided ablation in a milder AI-targeting setting.

Methods: Patients who underwent pulmonary vein isolation (PVI) for AI-guided atrial fibrillation ablation in our center were enrolled and divided into 2 groups according to the ablation power used. In the HP-AI group, the ablation power was over 45 W, while the low power-AI group was ablated with <35 W power. The targeted AIs were 450-500 in the anterior wall and 350-400 in the posterior wall. The efficacy outcome was expressed as the single-procedure atrial arrhythmia-free survival between 91 days and 1 year. Safety outcomes included severe adverse events (SAEs), including symptomatic pulmonary vein (PV) stenosis, atrioesophagal fistula, cardiac tamponade, stroke, thromboembolism events, myocardial infarction, and major bleeding.

Results: A total of 134 patients were enrolled, of whom 74 underwent PVI using HP-AI, while 60 received low power-AI ablation. After a mean follow-up time of 7.4 months, 22 (16.4%) patients showed arrhythmia recurrence: 5 (6.8%) patients in the HP-AI group and 17 (28.3%) patients in the low power-AI group. The HP-AI group showed a significantly higher arrhythmia-free survival than the low power-AI group ( = 0.011). Two patients in the low power-AI group and 1 patient in the HP-AI group developed an SAE ( = NS). Compared with the low power-AI group, the HP-AI group demonstrated a higher PV first-pass isolation rate, shorter ablation time, and fewer patients with anatomical leakages and sites of unreached AI.

Conclusion: In a milder AI setting, HP-AI ablation might result in significantly higher arrhythmia-free survival than low power-AI ablation and a similar safety profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9387669PMC
http://dx.doi.org/10.3389/fcvm.2022.949918DOI Listing

Publication Analysis

Top Keywords

ablation milder
12
atrial fibrillation
12
hp-ai-guided ablation
12
ablation
10
milder targets
8
power low
8
milder ai-targeting
8
ablation power
8
ablation index-guided
4
index-guided ablation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!