A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A uniformity correction method to reduce scan time for 7T sodium imaging of brain tumors. | LitMetric

A uniformity correction method to reduce scan time for 7T sodium imaging of brain tumors.

J Neuroimaging

Center for Clinical Spectroscopy, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.

Published: November 2022

Background And Purpose: Sodium imaging shows great potential for the characterization of brain tumors. Intensity correction is required but the additional scan time is costly. Recent developments can halve the time but were optimized in normal brains and may not be applicable in brain tumor imaging. We aim to develop an individualized uniformity correction for sodium imaging optimized for brain tumor patients that reduces scan time but provides high-resolution images for clinical practice.

Methods: Two-, 4-, and 6-mm iso-cubic voxel resolution birdcage coil images were used to calculate the 2-mm iso-cubic voxel individual sensitivity maps in healthy subjects (n = 3). Cut profiles were compared to determine the optimal approach. In addition, a 3-dimensional phantom was developed to test a generalized uniformity correction approach in both healthy subjects (n = 3) and tumor patients (n = 3).

Results: The cut profiles showed that the average correlation coefficient between 2- and 4-mm birdcage image correction results was r = .9937, and r = .9876 for 2- and 6-mm birdcage images. The correlation result between individual map correction and phantom map correction was r = .9817.

Conclusion: The 4 mm birdcage coil image provided the optimal approach for both as a compromise between the time-savings effect and image quality. This method allows for a 2-mm iso-cubic voxel resolution clinical sodium scan within 12 minutes. We also presented prescanned phantom sensitivity map results, which were designed to cover all patient head sizes. This approach provides an alternative solution in more time-sensitive cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9649857PMC
http://dx.doi.org/10.1111/jon.13041DOI Listing

Publication Analysis

Top Keywords

uniformity correction
12
scan time
12
sodium imaging
12
iso-cubic voxel
12
brain tumors
8
brain tumor
8
tumor patients
8
voxel resolution
8
birdcage coil
8
2-mm iso-cubic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!