Purpose: The purpose of this study is to report and compare outcome data of both primary and revision cases using a rotating hinge knee (RHK) implant.
Methods: This study retrospectively analyzed 63 cases (19 primary, 44 revisions) at a mean follow-up of 34 ± 8 months after RHK implantation. Outcome parameters were stability, range of motion (ROM), loosening, Hospital of Special Surgery Score (HSS), Knee Society Score (KSS), Oxford Knee Score (OKS), EQ-5D-3L, and Visual Analog Scale (VAS) for overall function. Revision rates and implant survival are reported.
Results: Eleven percent showed medio-lateral instability < 5 mm, a mean ROM of 115° ± 17° and radiologic loosening occurred in 8% (2% symptomatic). PROMS showed the following results: HSS 79 ± 18, KSS 78 ± 27, OKS 26 ± 10, EQ-5D index 0.741 ± 0.233 and VAS 70 ± 20. Primary cases revealed better outcomes in HHS (p = .035) and OKS (p = 0.047). KSS, EQ-5D index and VAS did not differ between primary and revision cases (p = 0.070; p = 0.377; p = 0.117). Revision rate was 6.3% with an implant survival of 96.8%.
Conclusions: RHK arthroplasty can be performed with good clinical outcome and low revision rate in revision and complex primary cases. RHK is an option in cases where standard arthroplasty and even implants with a higher degree of constraint have reached their limits.
Level Of Evidence: Level III, retrospective cohort study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10276093 | PMC |
http://dx.doi.org/10.1007/s00590-022-03349-1 | DOI Listing |
Sci Rep
December 2024
College of Information Engineering, SuQian University, SuQian, 223800, China.
The safety and reliability of rotating machinery hinge significantly on the proper functioning of rolling bearings. In the last few years, there have been significant advances in the algorithms for intelligent fault diagnosis of bearings. However, the vibration signals collected by machines are inevitably affected by irrelevant noise because of the complex working environments of bearings.
View Article and Find Full Text PDFAnat Rec (Hoboken)
December 2024
Biology Department, Northland Pioneer College, Holbrook, Arizona, USA.
Nothronychus graffami was a large therizinosaur represented by a single well-preserved individual from the Turonian Tropic Shale of southern Utah. It is characterized by an enlarged abdomen, small tail, and an extensively pneumatized axial skeleton, and is frequently regarded as herbivorous. Given the overall tail reduction and the development of a wide fused synsacrum with widely spaced acetabulae, it is reconstructed with an anteriorly rotated femur and a displaced resting ground reaction force anterior to the center of mass.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopedics Surgery, Shandong Provincial Hospital affiliated to Shandong First Medical University, 324 Jing Wu Road, Jinan, 250021, China.
Background: The present study aimed to compare the functional outcomes of hinged external fixators and non-external fixation in open elbow arthrolysis (OEA) for post-traumatic elbow stiffness (PTES) and to evaluate their applicability and limitations in patients with posttraumatic elbow stiffness.
Methods: The clinical data of patients with PTES treated with OEA at our hospital between March 2015 and June 2022 were retrospectively analyzed. The assessed variables were the operation time, intraoperative blood loss volume, duration of hospitalization, and treatment costs.
Knee Surg Sports Traumatol Arthrosc
December 2024
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Purpose: To investigate the biomechanical consequences of osteosynthesis of lateral hinge fractures (LHFs) in medial open wedge high tibial osteotomy (MOWHTO).
Methods: Sixteen fresh-frozen human cadaveric proximal tibiae underwent MOWHTO fixed with an ipsilateral locking compression plate. The specimens were assigned to two clusters simulating LHFs according to the Takeuchi classification: (1) Type II fracture; and (2) Type III fracture.
J Arthroplasty
December 2024
Ankara City Hospital, Department of Orthopedics and Traumatology, Ankara, TURKEY.
Background: Rotating hinge knee arthroplasty (RHKA) implants are often utilized as a salvage procedure in cases where bone stock is compromised. The aim of this retrospective study was to investigate whether residual collateral ligament integrity affects functional and radiographic outcomes in patients undergoing revision surgery with RHKA.
Methods: Patients treated with RHKA between 2011 and 2021 were eligible.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!