A DT neutron source-based prompt gamma ray neutron activation (PGNAA) facility for bulk sample analysis was designed and developed in this research. The aqueous samples containing chlorine and boron with known concentration were determined for the calibration curve by the facility. The neutron self-shielding effect was corrected by internal standard method. The minimum detectable concentration of boron and chlorine are 1.37 ± 0.42 and 12.51 ± 3.80 mg/L, respectively. Finally, five mixture aqueous solution samples were measured for the facility performance test. The maximum relative deviation of boron and chlorine are 4.49% and 5.32% respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2022.110394DOI Listing

Publication Analysis

Top Keywords

pgnaa facility
8
aqueous solution
8
boron chlorine
8
design neutron
4
neutron source
4
source based
4
based pgnaa
4
facility
4
facility element
4
element determination
4

Similar Publications

A radiation shield consists of borated polyethylene (7 % wt of boron) and lead was used for the HPGe detector in Isfahan MNSR's PGNAA facility in order to remove scattered neutrons and gamma rays, respectively. Therefore, the boron peak in gamma spectroscopy is related to both resources in the sample and in the shield, and it has caused a challenge in determination of boron concentration in the samples. In this research, various methods have been investigated to remove the effect of boron in the shield of the detector.

View Article and Find Full Text PDF

MCNP simulation and experimental study in situ low-grade copper analysis based on PGNAA.

Appl Radiat Isot

April 2024

Engineering Research Center of Ministry of Education for Nuclear Technology Application, East China University of Technology, Nanchang, 330013, China.

A prompt gamma neutron activation analysis (PGNAA) facility utilizing Cf source has been developed for in situ analysis of copper samples. Monte Carlo simulation is employed to determine optimal sizes for neutron moderator, gamma-ray shielding material, and thermal neutron absorber. Subsequently, based on the parameters optimized by MCNP, the PGNAA facility was constructed.

View Article and Find Full Text PDF

In this work, prompt gamma ray neutron activation analysis technique was used to monitor the REEs saturation in resin. A facility consisted of a D-T neutron generator, a BGO detector and a He detector was established and applied to analyze REEs (Gd and Sm) samples. Neutron self-shielding effect was also corrected.

View Article and Find Full Text PDF

A DT neutron source-based prompt gamma ray neutron activation (PGNAA) facility for bulk sample analysis was designed and developed in this research. The aqueous samples containing chlorine and boron with known concentration were determined for the calibration curve by the facility. The neutron self-shielding effect was corrected by internal standard method.

View Article and Find Full Text PDF

Since 2004, the k-standardization method has been applied and evaluated in three experimental channels at Es-Salam research reactor of the Algerian Centre de Recherche Nucléaire de Birine (CRNB). The NAA laboratory at CRNB is well involved in the implementation of the Prompt Gamma Neutron Activation Analysis to extend the field of analyses to some additional elements to the NAA method. In the frame work of the PGNAA research project, several works have been carried out in the present study including the experimental and simulation characterization of neutron and gamma flux parameters of the horizontal channel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?