Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: We evaluated the 1-year postoperative clinical and patient-reported outcomes in patients who had a 3-dimensional planned corrective osteotomy of their distal radius, radial shaft, or ulnar shaft using a printed, anatomical, patient-tailored plate to determine the feasibility and effectiveness of this methodology.
Methods: Simulations in computer-assisted preoperative planning of corrective osteotomies resulted in 3-dimensionally printed surgical guides, surgical models, and anatomically customized plates for application at the distal radius and forearm. Patients with malunions of the distal radius or forearm who underwent fixation with the custom-made plates were documented in our registry. Grip strength and range of motion assessments were made before surgery (baseline), as well as at 6 weeks and 3 and 12 months. Additionally, patients rated their wrist-related pain and disability using the Patient-Rated Wrist Evaluation.
Results: Fifteen patients underwent corrective surgery, and the 1-year follow-up data of 14 patients with a median age of 56 years (interquartile range, 24-64 years) were available for analysis. The median baseline Patient-Rated Wrist Evaluation score improved from 47 to 7 after 1 year. The flexion-extension arc of motion of the wrist increased from 90° at baseline to 130° at 1 year and the pronation-supination arc of motion of the wrist increased from 135° to 160° in the same time period. Differences in radiological measurements for palmar and radial inclinations, as well as for ulnar variance between the affected and contralateral wrists, were reduced with the osteotomy. In 1 case, the plate was removed 11 months after the osteotomy. No severe adverse events were reported.
Conclusions: Three-dimensionally planned and printed patient-tailored plates offer a reliable method for correcting even complex malunions of the distal radius and forearm.
Type Of Study/level Of Evidence: Therapeutic IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhsa.2022.06.021 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!